Installation and Operating Instructions Domestic HydroTap ® Filtered boiling and chilled drinking water for kitchens.
Installation Checklist Before Installation: A. Read the instructions B. Note: Not all fittings are supplied with the appliance kit. Isolation valves are not supplied C. Check the water pressure to determine if you require a pressure reduction valve or flow restrictor added or removed from the kit. D. Check the water quality to determine if extra filtration will be required. E. Check the appliance rating plate and ensure correct power is available for the appliance. F.
Contents Read These Warnings First . . . . . . . . . . . . . . . . . . . . . . . . . . 4, 5 Models covered by these instructions . . . . . . . . . . . . . . . . . . 6 Special tools required . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Installation Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Installation procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Step A - Installing the tap . . . . . . . . . . . . . . . . . . . . . . . . . . .
Read These Warnings First Safety This appliance is not intended for use by persons (including children) with reduced physical sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance. Refrigerant The Zip HydroTap Chilling unit contains 134A refrigerant under pressure.
Read These Warnings continued Filter Control (for filtered models) The Zip HydroTap filter control is preset to 6000 Litres to provide trouble-free flow and operation in most installations. Local water quality conditions may require an alteration to this capacity. In areas where the water has a high concentration of sediment, the preset litre capacity may be shortened to avoid poor flow, taste or odour situations.
Domestic models covered by these instructions Model Height mm Depth mm Width mm Weight empty kg’s Weight full kg’s 30009UK 334 320 188 9 11.5 37697UK 337 323 280 9.5 12 437677UK 348 380 385 26 30 Special tools required In addition to normal tools, the following will be required: • 35mm diameter sheet metal hole punch for sink tops. (not supplied) • 35mm diameter hole saw for timber bench tops. (not supplied) • Nut runner tube spanner (supplied) for fixing tap assembly.
Installation Requirements Before installing ensure that the following have been provided at the installation site: • Sufficient space in the cupboard to install the undersink unit in accordance with these Installation Instructions. A table of dimensions is given above. NOTE: Add 65mm to the Depth of the undersink unit to allow for Water and Electrical connections.
Installation procedure NOTE: Typical Layout is shown on P27 Step A - Installing the tap 1. Make sure that the tap location will allow the nozzle to drain into the sink. 2. Install the 35mm hole in the bench / sink top. Tap Black Plastic Spacer See note 3. All-thread rod Benchtop S/S Washer Spider Clamp Fixing nut Note: A stainless steel washer is supplied to go in between the Spider Clamp and the underside of the sink top. See location as shown. 3.
Installation procedure continued Step C - Connecting the tap Boiling ambient model Vent Ambient outlet Hot outlet Models 30009UK and 37697UK Measure and trim the red marked tube and / or the blue marked tube and connect it to the hot water outlet and ambient outlet (if an ambient model), on the top of the undersink unit. Use spring clamps provided. Measure and trim the unmarked tube and connect it to the vent outlet on the top of the undersink unit. Use spring clamps provided.
Installation procedure continued Step E - Testing and commissioning (applies to all models except HT boiling only) NOTE : New hose sets supplied with the unit should be used. Do not use old hose sets. Filter Flush Mode (filtered models only) The display screen will show which model you have. Have a bucket or similar container (not supplied) at the ready to hold a quantity of water that is ejected while the Filter Flush Mode is in operation.
Hydro Tap Installation and Operating Instructions - 89026UK - June 2009 Page 11 of 24
Page 14 of 24 Hydro Tap Installation and Operating Instructions - 89026UK - June 2009
Notes Installation procedure continued Chilled - Domestic Compact model When water and power are turned On, the Blue LED flashes slowly on the Tap Head assembly. The cold tank must be filled with water manually. Press the chilled water lever on the tap head and hold the lever down until cold water flows from the spout, then release. The compressor will start and when the water is chilled to 10ºC the Blue LED on the Tap Head assembly stops flashing and stays illuminated.
Font installation procedure 1. Position the Font template (provided) on the bench area. Ensure the position you select is within the length of the supply tube and USB cable fixed to the Tap Head Assembly. These cannot be extended. 2. Check again for correct positioning. The supply hoses must have constant fall back to the tank assembly. Cut the holes as shown on the template. 3.
Operating the Tap Blue Chilled Water Light On all the time: This indicates that the temperature of the chilled water is within the usable temperature range. Boiling Filter Change Chilled Flashing slowly : This indicates that the chilled water is not at the right temperature. Wait up to 20 minutes. When the chilled water is at the right temperature, the light will stop flashing. Note: The Zip HydroTap is designed to dispense chilled water in the temperature range 7°C to 14°C.
Child safety lock Child Safety Lock (HT boiling only models) Pressing the safety lock rapidly three times will either activate or de-activate the safety lock. Indicator light ON means the lock is active, indicator OFF means inactive. Lever Operation Press or pull lever Boiling Water Lever Depressing the “Red” lever allows dispensing of Boiling water. Pulling up the Red lever allows the tap to operate in a “no-touch” mode. Water will flow from between 5 and 15 seconds (This is user adjustable).
Setting the Energy Saver Timer (Model: 437677UK ) Plus Adjust Button Menu Plus Button Minus Adjust Button Menu Minus Button Normal Operation (not available on HT boiling only series) > > > > Set Time To change time, press either Menu or Menu button until Set Time is on the display screen. Press Adjust button to increase time or Adjust button to decrease time. Time increases or decrease in increments of one minute. Hold the Adjust buttons down for rapid increases or decreases.
Boiling Water Isolation (Model 437677UK) The HydroTap is equipped with an additional safety mode that allows protection against accidental operation by Infirmed or disabled persons. 2. Press adjust > 1. On the LCD scroll through the menu to Hot Isolation. to activate. 3. Now go to the Tap Head assembly and press the Safety Lock (3) three times rapidly, the LED’s will scroll from left to right (3) three times. This operation confirms the activation. 4. This isolates the boiling tap only.
Replacing the Filter (filtered models only) The Zip HydroTap notifies when filter replacement is due. The default setting is 6000 Ltrs, but this can be set in increments of 1000Ltr from 1000Ltr to 10000Ltrs. When a filter change is due, the Change Filter light will flash white once a minute and remain so until reset. A filter status light is located between the Red and Blue Lights on the tap head assembly.
Trouble Shooting Symptom Possible Cause Solution No LED display, no tap head lights or, no water when tap levers are operated. No power. Check power supply. Plug is not located in power socket. Ensure power plug is correctly fitted and switch is turned ON. Tap loom is not connected to HydroTap unit. Check loom connection. Possible internal fault. Contact local Zip Service Provider. Program in OFF cycle Check LCD for information. Water supply isolated. Check water supply is on.
Typical undersink layout Domestic Compact model 437677UK shown NOTE: The pressure limiting valve (supplied) must be fitted between the external service valve and the appliance Typical Boiling Only / Boiling Ambient unit Domestic Compact model 437677UK installation Hydro Tap Installation and Operating Instructions - 89026UK - June 2009 Page 23 of 24
Warranty Certain warranties may be implied by law into your contract with Zip. The warranty provided below is additional to these implied warranties and nothing set out below shall limit your statutory rights or rights at law.