Installation and Operating Instructions Autoboil ® Instant boiling water 01652 03652 05652 07652 Autoboil 1.5 Litre White Autoboil 3.0 Litre White Autoboil 5.0 Litre White Autoboil 7.5 Litre White Zenith Autoboil - Installation and Operating Instructions - 81433 - June 2012 v1.
Intentionally left blank. Page 2 of 12 Zenith Autoboil - Installation & Operating Instructions - 81433 - June 2012 v1.
Contents Read These Warnings First ............................ 4 Installation Requirements .............................. 4 Installation Procedures .................................. 5 Step 1 – Positioning ............... 5 Step 2 – Fastening................. 5 Step 3 – Connecting .............. 6 a) Plumbing ................6 b) Venting...................6 c ) Electrical ...............6 Step 4 – Assembling .............. 6 Step 5 – Commissioning .......
Read These Warnings First Please read all installation requirements, installation procedures and precautions before installing any Zenith Autoboil instant boiling water heater. Never attempt to install any Zenith Autoboil instant boiling water heater without reading all of the applicable instructions. In some hard water areas where mineral scale accumulation in the boiling chamber of the Zenith Autoboil may become a problem, consideration should be given to the maintenance required.
Installation Requirements continued isolation valve. d) Outlet drainage to a sink draining board or to a drip tray. e) Access to drainage from a vent situated at the base of the heater. If the water pressure is likely to exceed 7 bar (700 kPa), a 3.5 bar (350 kPa) pressure reducing valve must be installed in the cold water supply line. f) In all installation instances the walls of the heater must be vertical and the base horizontal, there can be no exceptions to this rule.
Installation Procedures Continued Step 3 – Connecting a) Plumbing For exposed plumbing connection, connect the cold water inlet pipe from the base of the heater directly to the 1/2” or 12.7 mm compression fittings. 250mm For concealed plumbing connections, connect the cold water pipe through the rear of the chassis using a 1/2” or 12.7 mm capillary elbow (# 63 Swivel Elbows). 45 mm Concealed Inlet Wring Concealed Vent Cold water pipes must be flushed before connection to the inlet.
Wall Mounting Template Dimensions & Electrical Diagram 274 (1.5L & 3.0L) 304 (5.0L & 7.5L) 1.5L & 3.0 L 5.0 L &7.5 L 150 CLEAR 38 (1.5L & 3.0L) 53 (5.0L & 7.5L) 19 318 5.0L 416 3.5L 448 5.0L 561 7.5L 65 CLEAR 56 POSITIONING PIN COLD INLET VENT EXTERNAL PLUMBING ELECTRICAL WIRING POSITION INTERNAL PLUMBING 72 15 25 35 42 BENCH TOP Zenith Autoboil - Installation and Operating Instructions - 81433 - June 2012 v1.
Problem Solving Symptom Possible Cause Solution Fails to dispense water. Water isolating valve turned off. Blocked filter, blocked meter tube, blocked strainer, jammed ball valve assy, airlock in transfer tube. Check water supply valve. Contact Zenith authorised agent. No power. Water not boiling. Runs out of boiling water and fails to refill. Outlet tap drips. Overflow from vent. Excessive steam from vent. Power “on” but no heat. Overload repeatedly tripping with excessive steam.
Operating Procedures Tap Operation Boiling water Autoboil is fitted with a two-way cool-touch safety tap for filtered instant boiling water. For instant boiling water, gently pull the top of the tap forward. Boiling water will flow until the tap handle is released. This operation gives fingertip flow control for safe filling of cups and mugs. To fill larger vessels such as teapots and saucepan’s, rotate the tap 180 degrees and depress it until it locks into a horizontal position.
Spare Parts Page 10 of 12 Key Part No Description 1 90487NZ Cistern Lid Clamp kit 2000B 2 90488NZ Cistern Lid and Gasket kit 2000B 3 90490NZ Gasket kit Autoboil 2000B 4 90083NZ Float valve kit w/ seals 2000B 5 90069NZ Jumper valve kit w/ seals 2000B 6 90102NZ Cistern float kit w/ nut and screw 7 90493NZ Metering tube kit 1500w 2000B 7 90494NZ Metering tube kit 2400w 2000B 8 90495NZ Banjo screw Autoboil 2000B Version 2 9 90496NZ O-Ring kit Autoboil 2000B 10 90574NZ Fascia
Spare Parts Zenith Autoboil - Installation and Operating Instructions - 81433 - June 2012 v1.
Contact Information Registering your product: Registering your Zenith installation on the Zenith Heaters Limited website may help to establish date of installation, should it become necessary to service the appliance, under the terms of Zenith Heaters Limited warranty. To register your installation go to www.zenithheaters.co.nz and look under the heading “Warranty”. As Zenith Heaters Limited policy is one of continuous product improvement, changes to specifications may be made without prior notice.