Instruction manual

67ZVC235-001_v03
WeadviseyoutoreplacetheEPAE12basiclter
(14)withanewoneevery6monthsofuse.
AlwaysreplaceadamagedEPAE12basiclter
withabrandnew,originalone.
OUTLET MICROFILTER
1
In order to replace the outlet microlter (13) press the
blocking mechanism on the cover of the outlet lter, and then
remove the cover of outlet lter out of the vacuum cleaner.
2
Remove the outlet lter from the cover.
If the outlet microlter (13) is dirty, you may replace it with
a new one, clean it or rinse it with running water. Before
reinstalling the lter, make sure it is dry.
Forsafetyreasons,itisunacceptabletoinstall
awetordamagedoutletmicrolter.
3
Situate the new/rinsed lter carefully onto the
4 fastenings of the outlet lter cover with the foam sides
towards themselves.
4
Place the lter cover in such a way that the two
protrusions situated in the lower part of the cover are
inserted into the holes in the body of the vacuum cleaner,
and then press the lter cover to snap the fastening in the
body shut. A characteristic “click” signalizes the lter cover
has been properly installed.
Always replace a damaged microlter with
abrandnew,originalone.
Special accessories
The following special accessories may be purchased in retail
outlets:
Parquet brush “BNB” (22)
Is used to clean and polish hard, scratch sensitive surfaces
such as wooden oors, oor panels, parquet, marble, tiles, etc.
Delicate and soft natural bristles ensure maximum vacuum
effectiveness and protects against scratching the cleaned
surface.
After-work procedures, cleaning and
maintenance
1
Press the on/off button to stop the vacuum cleaner.
2
Remove the plug of the cord from the socket.
3
Wind the cord by pressing the cord winder button (8).
Hold the cord when doing it to avoid tangling the cord up or
letting the plug hit the vacuum cleaner.
4
Disconnect the telescopic suction pipe from the nozzle or
brush.
5
Disconnect the suction tube from the hose. In order
to remove the telescopic tube from the hose handle,
simultaneously press the lock A and pull the tube in the
direction indicated by the arrow.
E
F
It is forbidden to wash lters in washing
machinesordishwashers.
Filtersmaybedriedonlynaturally.
Donotusehairdryers,heatersorradiatorsto
drylters.
Before replacing the lters make sure the
vacuumcleanerisoff,andtheplugofthecord
isunpluggedfromthesocket.
EPA E12 BASIC FILTER
It is necessary to periodically clean the EPA E12 basic lter
to remove small fractions of dust.
Remove the CYKLON dust container and empty it, as
described in para. C.
1
Pull the fastenings on the cover of the CYKLON dust
container aside, and remove the cover from the container.
If the CYKLON dust container is full, empty it as described in
para. C.
2
Remove the protective casing of the EPA E12 basic
lter out of the dust container. In order to do this turn the
protective casing of the EPA E12 basic lter in the direction
given on the symbol (it is situated along with an arrow
on the protective casing of the EPA E12 basic lter).
Clean, wipe, and carefully dry the casing.
3
Remove the EPA E12 basic lter from the container
Clean the pleats of the EPA E12 basic lter (14), and if
the lter is damaged, it should be denitely replaced with
a new one. If the EPA E12 basic lter (14) is dirty, you
may replace it with a new one, clean it or rinse it with
running water. Before reinstalling the lter, make sure it
is dry.
Forsafetyreasonsitisunacceptabletoinstall
awetordamagedEPAE12basiclter(14).
4
Place the new/rinsed EPA E12 basic lter (14) in the
previously determined spot in the dust container.
5
Situate the protective casing of the EPA E12 basic lter
in the chamber of the container, in the previously determined
spot. Pay attention that the protrusions situated on the ange
of the container are inserted in the sockets of the body of the
container.
6
Turn the protective casing of the EPA E12 basic lter in
the direction given on the symbol (it is situated along
with an arrow on the protective casing of the EPA E12 basic
lter).
7
Place the cover of the CYKLON dust container on the
container in such a way that the fastening situated in the
front part of the cover is inserted into the projection of the
container. Press the back part of the cover in such a way that
the fastenings are shut tight on the body of the container.
8
Situate the CYKLON dust container with the installed
EPA E12 basic lter (14) in the chamber of the vacuum
cleaner. Close the upper cover of the vacuum cleaner by
pressing it, until you hear a characteristic “click.”
D