Operating instructions
22
• Two filter cover caps F
• Tightly closing motor bypass flap G
• Bypass flap covering H
• Highly efficient reverse flow channel heat exchanger or a membrane moisture heat exchanger I
• Two high capacity fans with constant speed J
• Heat exchanger covering K
• Foam cover plate for the fans L
• Control boards M
• Plastic cover plate for the control N
• Interface sheet O
Figure 15: Exploded view of the main components
3.3 Installation Requirements
In order to be able to judge if it is possible to install the novus in a certain room, the following points have
to be observed:
• Novus has to be installed in accordance with the general as well as the local safety and
installation instructions of the electric works and water works among others as well as according to
the instructions of this operating manual.
• The place of the installation has to be selected in such a way that there is enough space at the
sides of the novus for air connections and for performing maintenance works.
• The following equipment has to be available in the installation room:
- air duct connectors.
- 230 V power supply.
- connectivity for the condensate drain.
• Novus has to be installed in a frost protected room. The condensate has to be drained off frost-
free, with a gradient and by using a siphon.