User guide

1.8 Color management
AG50241 Rev. 4 39
4. In the Harlequin RIP, click Output > Calibration Manager to open the Calibration
(Dot Gain) Manager. In the Manager click
Device and select the correct device,
and then click
New to open the Edit uncalibrated target for… window.
5. In Edit uncalibrated target for…, click
Profile and select the correct paper/reso-
lution type. All other options should be left at their default settings (ensure
Force
solid colors remains unchecked).
6. In the
Name field, enter an appropriate name for the initial profile, for example
HP Heavy Coated 300-1 and click Import > Import to read the calibration
data.
7. Click
OK until all open windows are closed.
Print and measure a second target
1. Open your page setup (the one you used to print the initial target). From the
Calibration list, select the calibration profile you just created
(
HP Heavy Coated 300-1) then click OK to close the page setup window.
2. Open the Print Calibration window. Select your page setup and click
Print calibrated target (note this time you are selecting calibrated target). Mea-
sure the printed target.
3. Open the Calibration (Dot Gain) Manager. Select the appropriate device and
choose the calibration profile that you made with the initial target.
4. Click the
Copy button to create a duplicate of the profile. From the list select the
copy and click
Edit from calibrated target to open the Edit calibrated target for…
window.
5. Change the name of the profile to
HP Heavy Coated 300-2 and click Import >
Import
to add the calibration set.
6. Click
OK until all open windows are closed.
Print and measure a final target
1. In the RIP, open your page setup and from the
Calibration list select
HP Heavy Coated 300-2. Click OK to close the window.
2. Open the Print Calibration window. Select your page setup and click
Print calibrated target. Measure the target with Genlin or your favorite calibra-
tion program.