Product Manual

S1220, Rev C
July 2009
No
smoking
Safety gloves
must be worn
Wear your
safety glasses
Safety overalls
must be worn
1. Always wear protection gear like safety goggles, gloves, apron, and ear plugs while operating the pump
2. Never let any body part come in front of, or in contact with the control valve outlet
3. Always cut off air supply after use, so that media can't leak incase any of the pump component fails
4. Before attempting any maintenance or repair of this product, disconnect air supply and then squeeze control valve trigger to
release fluid pressure
5. Before switching the air supply on, check hoses for sign of wear, leak or loose fittings. Replace as necessary
6. In case of accident, immediately seek medical attention. Do no try to treat the injury yourself
7. Use only genuine factory parts for repair
8. Do not smoke when using / near the pump
9. Do not use the pump near a source of spark / open flames
10.In case of change of working fluid, at least 1 liter (or as desired) of new fluid should be discarded to avoid mixing of fluids
11. Operate pump for not more than 4 hours continuously
12. Use only natural compressed air for operating the pump
TROUBLESHOOTING
Pump does not dispense fluid
PROBLEM CAUSES REMEDYSr. Nr
1.
1.Pump not able to create adequate suction
2.Drum is Empty
3.Pump inlet is blocked
4.Inlet Pressure is too Less
5.Drum is not vented
1. Make sure that media used has a
viscosity of SAE 130 or lower .Make
sure all threaded connections are air
tight
2. Media level inside the drum may be
too low. Change drum
3.Remove suction tube & clean strainer
at pump inlet
4. Inlet Air Pressure must at least be
30 PSI (2 BAR).Increase inlet pressure
5. Open small drum plug on the drum
Air Motor does not work
2
Air motor may have ceased due to
inadequate lubrication
Send pump to distributor for repair
Air motor operates even without
actuating the dispensing gun
3
Leakages in the assembly Check all connections to ensure they
are air tight
CAUTIONS