Operation Manual
Routine Maintenance
Cleaning Schedule and Procedures
138
P1048261-005 11/5/15
4. Using the swab from a Zebra Preventive Maintenance Kit, wipe along the brown strip on
the printhead assembly from end to end. In place of the Preventive Maintenance Kit, you
may use a clean swab dipped in 99.7% isopropyl alcohol. Allow the solvent to evaporate.
5. While manually rotating the platen roller, clean it thoroughly with the swab. Allow the
solvent to evaporate.