User's Manual
Table Of Contents
- Contents
- About This Document
- Introduction
- Commands
- Immediate Commands
- Print Commands
- Advanced Mode, Select
- Alphanumeric Field Separator
- Batch Count, Set
- Clear All Data
- Clear Data From Current Field
- Command Terminator 1
- Command Terminator 2
- Configuration Parameters, Transmit
- Cut
- Data Shift – International Characters
- Direct Graphics Mode, Select
- Emulation Mode, Enter
- Field, Select
- Field Decrement, Set
- Field Increment, Set
- First Data Entry Field, Select
- Font, Transmit
- Form Feed
- Format, Select
- Format, Transmit
- Increment and Decrement, Disable
- Memory Usage, Transmit
- Next Data Entry Field, Select
- Numeric Field Separator
- Options Selected, Transmit
- Page, Select
- Page, Transmit
- Printhead Parameters, Transmit
- Program Mode, Enter
- Program Number, Transmit
- Quantity Count, Set
- Start and Stop Codes (Code 39), Print
- Test and Service Mode, Enter
- User-Defined Characters, Transmit
- User-Defined Tables, Transmit
- Warm Boot
- Configuration Commands
- Amount of Storage, Define
- Auto-Transmit 1, Enable
- Auto-Transmit 2, Enable
- Auto-Transmit 3, Enable
- Auto-Transmit 1, 2, and 3, Disable
- Cutter, Enable or Disable
- Dark Adjust, Set
- Emulation or Advanced Mode on Power-Up
- End-of-Print Skip Distance, Set
- IBM Language Translation, Enable or Disable
- Intercharacter Delay, Set
- Label Rest Point, Adjust
- Label Retract, Enable or Disable
- Label Retract Distance, Set
- Label Stock Type, Select
- Label Width, Set
- Maximum Label Length, Set
- Media Sensitivity, Select
- Message Delay, Set
- Number of Image Bands, Set
- Postamble, Set
- Preamble, Set
- Print Speed, Set
- Printer Language, Select
- Printhead Loading Mode, Select
- Self-Strip, Enable or Disable
- Top of Form, Set
- Program Mode Commands
- Bar Code, Select Type
- Code 39
- Code 93
- Interleaved 2 of 5
- Code 2 of 5
- Codabar
- Code 11
- Code 128
- UPC/EAN
- HIBC Code 39
- Code 16K
- Code 49
- POSTNET
- PDF417
- Using ,m1 to Select the Number of Columns
- Using ,m2 to Select an Error Correction Level
- Using ,m3 to Set the Truncate Flag
- MaxiCode
- JIS-ITF
- HIBC Code 128
- Data Matrix Symbology Versions ECC-100 and ECC-200
- QR Code
- MicroPDF417
- Bar Code Field, Create or Edit
- Bitmap Cell Height for Graphic or UDF, Define
- Bitmap Cell Width for Graphic or UDF, Define
- Bitmap User-Defined Font, Clear or Define
- Border Around Human-Readable Text, Define
- Box Field, Create or Edit
- Character Bitmap Origin Offset, Define
- Character Rotation or Bar Code Ratio, Define
- Code 39 Prefix Character, Define
- Command Tables, Load
- Current Edit Session, Save
- Data Source for Format in a Page, Define
- Field, Delete
- Field Data, Define Source
- Field Direction, Define
- Field Origin, Define
- Font Character Width, Define
- Font Type, Select
- Format, Create or Edit
- Format Direction in a Page, Define
- Format, Erase
- Format Offset Within a Page, Define
- Format Position From Page, Delete
- Format Position in a Page, Assign
- Graphic, Select
- Graphic or UDC, Define
- Height Magnification of Bar, Box, or UDC, Define
- Human-Readable Field, Create or Edit
- Intercharacter Space for UDF, Define
- Interpretive Field, Edit
- Interpretive Field, Enable or Disable
- Length of Line or Box Field, Define
- Line Field, Create or Edit
- Outline Font, Clear or Create
- Outline Font, Download
- Page, Create or Edit
- Page, Delete
- Pitch Size, Set
- Point Size, Set
- Print Line Dot Count Limit, Set
- Program Mode, Exit
- User-Defined Character, Clear or Create
- User-Defined Character Field, Create or Edit
- User-Defined Font Character, Create
- Width of Line, Box, Bar, or Character, Define
- Test and Service Commands
- Ambient Temperature, Transmit
- Command Terminator
- Dark Adjust
- Factory Defaults, Reset
- Formats, Print
- Hardware Configuration Label, Print
- Label Taken Sensor Value, Transmit
- Pages, Print
- Pitch Label, Print
- Print Quality Label, Print
- Printhead Temperature Sensor Value, Transmit
- Reflective Sensor Value, Transmit
- Software Configuration Label, Print
- Test and Service Mode, Exit
- Transmissive Sensor Value, Transmit
- User-Defined Characters (UDC) and Graphics, Print
- User-Defined Fonts, Print
- Set-Get-Do (SGD) Commands
- Network Configuration
- Control Panel Options
- Index

109
Control Panel Options
S4M LCD Options
11/24/09 APL-I Reference Guide 14177L-003
Table 5 shows the protected menu for ADVANCED SETUP 3. To access this, see S4M
Password Protected Menus on page 106.
Table 5 • S4M Protected Menu
LCD Details
PRINT OUT
This allows you to print certain types labels with specific
printer information.
PRINT PAGE
This allows you to print the stored APL-I page.
PRINT FORMAT
This allows you to store and print up to 100 formats.
PARALLEL COMM.
This allows you to select a communications port. It must
match the one being used by the host.
BAUD
This allows you to select a baud rate. It must match the rate
being used by the host.
DATA BITS
This allows you to select the data bits. It must match the data
bits being used by the host.
STATUS RESP
This determines if a response is sent after inquiry commands.
PARITY
This allows you to select the parity. It must match the parity on
the host.
HOST HANDSHAKE
This allows you to select the handshake protocol. It must
match the protocol on the host.
ACTIVE PRINTSRVR
This allows you to see which print server is being used.
OBTAIN IP ADDRESS
This allows you to select the method by which an IP address
will be assigned to the printer.
IP PROTOCOL
The allows you to see if the user (permanent) or the server
(dynamic) selects the IP address.
IP ADDRESS
This allows you to modify this setting, only when Permanent is
select for OBTAIN IP ADDRESS.
SUBNET MASK
This allows you to view the subnet mask.
DEFAULT GATEWAY
This allows you to view the default gateway.
HEXDUMP
This allows you to check the connection between the printer
and the host computer.
CHANGE RTC DATE
This allows you to view the current date and change the date.
CHANGE RTC TIME
This allows you to view the current time and change the time.
LOAD DEFAULTS
This allows you to reset the parameters back to the factory
default settings.
DEFAULT NET
This restores the wired and wireless network settings back to
factory defaults.
INIT FLASH MEM
This allows you to reformat your Flash memory.