User Manual

Table Of Contents
Troubleshooting
258
Resolution
1 Clean the ribbon cartridge’s smart chip contact, if they look contaminated, with alcohol and a lightly
moistened cotton. Try a different cartridge if this does not work.
2 — Clean the Ribbon Cartridge Sensor Contact Pins - see Cleaning Ribbon Cartridge Sensor.
3 — Reload printer firmware. See s.
4 — If the printer does not recover from this error, call a service technician. This is not a user serviceable
item.
Issue: Battery has a Red Indicator
Battery has a fault.
Possible Cause - 1
The battery has reached its usable life or has a general component failure.
Possible Cause - 2
Battery is too hot or too cold
Resolution
1 — Remove the battery from the printer and check charge status by charging the battery.
2 — Let the battery cool down or warm up to ambient temperature and recheck the battery charge.
3 — Replace the battery.