User Manual

Table Of Contents
ZPL Configuration
342
From this point in the Configuration Receipt listing, the printout has sensor settings and values displayed to
troubleshoot sensor and media operations. These are typically used by Zebra Tech Support to diagnose
printer problems.
** - Not supported with a ZPL command, uses the Set Get Do command in the ZPL manual. Refer to
device.command_override.xxxxx in the ZPL Programmer’s manual.
Table 3 ZPL Commands and Configuration Report Callout Cross-Reference
Command Listing Name Description
~SD
DARKNESS Default: 10.0
DARKNESS SWITCH LOW (Default), MEDIUM, or HIGH
^PR
PRINT SPEED Default: 152.4 mm/s / 6 IPS (max.) - 203 dpi
     101.6 mm/s / 4 IPS (max.) - 300 dpi
~TA
TEAR OFF Default: +000
^MN
MEDIA TYPE Default: GAP/NOTCH
SENSOR SELECT Default: AUTO (
^MNA - Auto-Detect)
^MT
PRINT METHOD THERMAL-TRANS or DIRECT-THERMAL
^PW
PRINT WIDTH Default: 448 (dots for 203 dpi) or 640(dots for 300 dpi)
^LL
LABEL LENGTH Default: 1225 (dots) (dynamically updated while printing)
^ML
MAXIMUM LENGTH Default: 39.0IN 989MM
USB COMM. Connection Status: Connected / Not Connected
^SCa
BAUD Default: 9600
^SC,b
DATA BITS Default: 8 BITS
^SC,,c
PARITY Default: NONE
^SC,,,,e
HOST HANDSHAKE Default: AUTO
^SC,,,,,f
PROTOCOL Default: NONE
SGD—**
COMMUNICATIONS Default: NORMAL MODE
SER COMM. MODE Default: AUTO
^CT/~CT
CONTROL CHAR Default: <~> 7EH
^CC/~CC
COMMAND CHAR Default: <^> 5EH
^CD/~CD
DELIM./CHAR Default: <,> 2CH
^SZ
ZPL MODE Default: ZPL II
SGD—**
COMMAND OVERRIDE Default: INACTIVE
^MFa
MEDIA POWER UP Default: NO MOTION
^MF,b
HEAD CLOSE Default: FEED
~JS
BACKFEED Default: DEFAULT
^LT
LABEL TOP Default: +000
^LS
LEFT POSITION Default: +0000
~JD/~JE
HEXDUMP Default: NO (
~JE)
REPRINT MODE Default: DISABLED