User Manual

Table Of Contents
Color Touch Display and Controls
83
System > Settings > Power Up Action
Set the action for the printer to take during the power-up sequence.
Accepted values:
CALIBRATE—Adjusts sensor levels and thresholds, determines the label length, and feeds the media
to the next web.
FEED—Feeds the labels to the first registration point.
LENGTH—Determines the label length using current sensor values, and feeds the media to the next
web.
NO MOTION—Tells the printer not to move the media. You must manually ensure that the web is
positioned correctly, or press feed to position the next web.
SHORT CAL—Sets the media and web thresholds without adjusting sensor gain, determines the label
length, and feeds the media to the next web.
Related ZPL command(s): ^MF
SGD command used: ezpl.power_up_action
Printer web page: View and Modify Printer Settings > Calibration