Owner's manual

System Troubleshooting
1-5
1.1.7 Console Port is Not Responding
The WS5000 Series Switch console port is physically connected to the host computers serial port, but pressing
the [Enter] key gets no response from the switch. Table 1.6 provides suggestions to troubleshoot this issue.
1.1.8 WS5000 CLI Prompt Displays DIAG>
The WS5000 Series Switch changes into the diagnostics mode, displaying the DIAG> prompt, when it
encounters a critical internal failure, such as when the switch is unable to start. This is a fatal error that should
never happen.
From the DIAG> prompt, the following options are available:
•reset
shutdown
restore
Before contacting the Symbol Support Center, perform the following suggested corrective actions:
1. From the DIAG> prompt, invoke the reset command.
DIAG> reset
This command resets the system.
2. From the DIAG> prompt, invoke the restore default configuration command:
DIAG> restore <default config>.cfg
3. From the DIAG> prompt, invoke the restore system image command. Restore a known good image, not
the image used when the switch went into diagnostics mode.
DIAG> restore WS5000_x.x.x.0-00xx.sys.img
Table 1.6 Console Port is Not Responding Troubleshooting Notes
Possible Issue Suggestions to Correct
Cabling issue Ensure that a NULL-modem cable is connected from the WS5000 console port to the
host computers serial port.
Not using a terminal
emulation program
Verify that a serial terminal emulation program, such as HyperTerminal, is in use.
Settings in terminal
emulation program are
incorrectly set
Check the serial port settings in the serial terminal emulation program being used. The
correct settings are:
All else... Contact Symbol Support.
Terminal Type VT-100
Port COM 1-4
Terminal Settings 19200 bps transfer rate
8 data bits
no parity
1 stop bit
no flow control