User guide
ZPL Commands for Wireless Operation
^KC
94
14143L-005 Rev. A Wireless User Guide 4/29/08
^KC
Set Client Identifier (Option 61)
Description The ^KC command allows the print server to have its own client identifier
(CID).
Format ^KCa,b,c,d
The following table identifies the parameters for this format.
* This applies only to the Zebra ZM400™, ZM600™, RZ400™, or RZ600™ printer when it is used with the
external ZebraNet 10/100 print server using firmware v1.1.5.
Parameters Details
a = enable or disable Accepted Values:
0 = disable (default)
1 = enabled, use MAC address
2 = enabled, ASCII value
3 = enabled, HEX value
Default Value: 0
b = device Accepted Values:
0 = all devices
1 = wireless
2 = external wired *
3 = internal wired
Default Value: 1
c = prefix (optional) Accepted Values: 11 ASCII characters or 22 hexadecimal
values.
The prefix can be cleared by defaulting the network settings
on the printer.
d = identifier Accepted Values: 60 ASCII characters or 120 hexadecimal
values. Minimum field length is 2 bytes.
The suffix can be cleared by defaulting the network settings
on the printer.