Specifications
Command Reference
System Related Commands
36
P1003645-001 TTPM2™ Installation and Programming Manual 03/05/2009
Reads a value indicating the number of bytes actually printed on the ticket (both blank and non
blank). The number consists of 4 hexadecimal digits and should normally be equal to 5BE0. A
lower number together with the absence of the 03H indicates that the last ticket was not fully
printed and a decision may be taken whether the system should reissue the ticket or alert the
supervisor.
This is a safety feature to minimize the risk of valid tickets being duplicated without attention
from the system, by turning off the power at a certain point.
Sets the resolution of the print. This only affects the resolution in the transport direction of the
ticket. 0=normal resolution, (5.7dots/mm). 1=high resolution (8.5 dots/mm).
Reads out the internal ticket counter from the control board. This counter starts from 0 when
the printer is new and is incremented by one fore each completed !P sequence.
The result is sent as 12 decimal digits + CR + LF
Reads out the internal retract counter. This counter is incremented by one for each ticket that is
retracted and thrown in the wastebasket.
To reset the counter to zero, send the command:
C1
The result is sent as 12 decimal digits + CR + LF
!W Read thermal print progress indicator
a
a. Introduced in firmware version 3.32
!X Set resolution
!Y Read ticket counter
a
a. Introduced in firmware version 3.60
!Y1 Read retract counter
a
a. Introduced in firmware version 4.24
Note •
Retract function is only available on printers with FL2 and FL3.