Technical information
Sometimes the standard procedure will not work with especially heavy media
backing material. In this case, the printer fails to calibrate, goes into PAUSE
mode, and the Paper/Ribbon light comes ON. If this happens, perform this
supplemental procedure. Make sure that you perform the regular procedure
BEFORE performing this procedure.
1. Remove the Electronics Cover to allow access to the Main Logic Board.
2. Print a Media Sensor Profile by pressing the Mode key once after the printer
completes the Power On Self Test. At this point, the Media Sensor Profile
will look something like the one shown in Figure 5.5.
3. As the Media Sensor Profile is printing, adjust the Media Sensor
Potentiometer while viewing the profile until the peak and the background
are distinctly separated (see Figure 5.5). If the peak is being printed in the
interlabel gap, view the resulting peak on the used ribbon instead.
4. Replace the Electronics Cover and reload ribbon and media.
5. Cycle power OFF then ON to resume printing.
Page 5-6 44868L