Reference guide
12 STB20XX Single Slot Cradles
Lost Connection to Host
If scanned data does not transmit to the cradle’s host, ensure that all cables are
firmly inserted and the power supply is connected to an appropriate AC outlet, if
applicable. If scanned data still does not transmit to the host, reestablish a
connection with the host:
1. Disconnect the power supply from the cradle.
2. Disconnect the host interface cable from the cradle.
3. Wait three seconds.
4. Reconnect the host interface cable to the cradle.
5. Reconnect the power supply to the cradle, if required.
6. Reestablish pairing with the cradle by scanning the pairing bar code.
Charging the Scanner Battery in the Cradle
To charge the scanner battery, place the scanner in the cradle (see Inserting the
Scanner in the Cradle on page 11). The battery begins charging when the scanner
LED indicator starts flashing green. A complete charge of a fully discharged
battery can take up to four hours using external power and up to 10 hours using
the interface cable.
LED Indicators
Scanner LED Indicators
Off No power applied to scanner (battery discharged or removed);
scanner is in low power and ready to scan; or, battery is fully
charged and scanner is ready to scan.
Green Flash Scanner is charging (when cradle is powered from external
power supply).
Red Flash Charging problem or data transmission problem.
Cradle LED Indicators
Solid Blue Cradle is powered.
NOTE Additional cradle LED information:
STB2000 cradle - blue LED is off when there is a USB connection but no AC
power connection.
STB2078 cradle - blue LED lights when there is a USB connection but no AC
power connection.