User guide

59
RW Series User Guide
continued
Troubleshooting Topics
1. No power
Check that battery is installed properly.
Recharge or replace battery as necessary. (Always dispose
of used batteries properly. Refer to Appendix E for more
information on proper battery disposal.)
2. Media does not feed:
Ensure Media Cover is properly closed and latched.
Check media supports for any binding.
3. Poor or faded print or ashing icon:
Clean print head.
Check battery and recharge or replace as necessary.
Check quality of media.
4. Partial/missing print:
Check media alignment.
Clean print head.
Ensure Media Cover is properly closed and latched.
5. Garbled print:
Check baud rate.
6. No print:
Check baud rate.
Replace battery. Always dispose of used batteries
properly. Refer to Appendix E for more information on
proper battery disposal.
Check cable to terminal.
Wireless units (Bluetooth or 802.11b/g) only: Establish RF
Link. Restore LAN associativity on 802.11b/g wireless units.
Invalid label format or command structure — put printer in
Communications Diagnostic (Hex Dump) Mode to diagnose
problem (refer to Troubleshooting Tests section).
7. Reduced battery life
Check battery date code — if battery is one to two years
old, short life may be due to normal aging.
Replace battery. (Always dispose of used batteries
properly. Refer to Appendix E for more information on
proper battery disposal.)
8. Flashing icon:
No application or application corrupted: reload program.
Flashing indicator is normal while data is being received.