User guide
Appendix B: Diagnostics Output Data (D-packets)
D2119 Dart RTLS User Guide 121
Health tag battery OK
Description: A health tag configured at location (x, y, z) recovered from battery
low condition. When a health tag gets into battery low condition, once its
battery status is at a value above the threshold, it exits from battery low
condition and send this D-packet once
Recommended Action: None.
Message Type: This event packet will be sent only once after the health tag
exits from battery low condition.
Message Format:
Dart: D,hthTagID,x,y,z,battery,timestamp,DpacketID,‘Health tag battery OK’
Health tag not found
Description: A health tag with tag ID <hthTagID>, configured to be at location
(x,y,z), has lost signal for more than 20 seconds. The <battery> represents the
tag battery level at the last detection time, and <timestamp> is the UNIX time
(i.e. the number of elapsed seconds since January 1, 1970, UTC), at which the
health tag signal was last detected.
Recommended Action: Verify the health tag is present and not damaged.
Message Type: This warning packet will be sent only once when the health tag
has not been detected for 20 seconds
Message Format:
Dart: D,hthTagID,x,y,z,battery,timestamp,DpacketID,‘Error: Health tag not
found’
Health tag detected
Description: A health tag with tag ID <hthTagID>, configured to be at location(
x,y,z), is detected with a tag battery level of <battery> at UNIX time of
<timestamp>.
Recommended Action: None.
Message Type: This event packet will be sent only once when the health tag is
detected for the first time since firmware restart or it had been reported as lost.
Message Format:
Dart: D,hthTagID,x,y,z,battery,timestamp,DpacketID,‘Health tag detected’
NTP sync succeeded
Description: NTP synchronization succeeded at UNIX time of <timestamp>.
Recommended Action: None.
Message Type: This event packet will be sent only once when the NTP
synchronization succeeds.
Message Format:
Dart: D,0,0,0,0,0,timestamp,DpacketID,‘NTP synchronization succeeded’
NTP sync failed
Description: NTP synchronization failed at UNIX time of <timestamp>.
Recommended Action: None.
Message Type: This event packet will be sent after every retry to attempt to
sync with the NTP server.
Message Format:
Dart: D,0,0,0,0,0,timestamp,DpacketID,‘Error: NTP synchronization failed’
Remote Hub Connection
failed
Description: An attempt to connect to a remote hub failed at UNIX time of
<timestamp>.
Recommended Action: Check network cable and whether remote hub is
functioning.
Message Type: This event packet will be sent after every retry to connect with
the remote hub and will persist until a connection can be established.
Message Format:
Dart: D,0,0,0,0,0,timestamp,DpacketID,‘Error: Remote hub connection failed’