User guide

Status
D2119 Dart RTLS User Guide 103
receiver is not configured.
Presence Detect: Indicates a receiver (RTLS or Proximity) is configured to output
presence data. This is left blank if the receiver is not configured.
Read Range: Read range setting of a receiver (1 25 in coarse range control mode or 1
54 in fine range control mode). When blank, the receiver is not configured.
Remote Rx#: Receiver number of the receiver as configured on the remote hub. This field
is 00 if the receiver is local or not remote.
Remote Hub: IP address of the remote hub that a remote receiver physically connected
to. This field is all zeros if the receiver is local or not remote.
3 Click Save Receiver List to save all the receiver information to a text file for future reference.
Viewing Tag status
The Tag Status tab shows reference tag status and active tag detected.
To view Receiver status:
1 Start the Hub Administration and Management application, click Status.
2 On the Tag Status tab, examine the displayed information.
Component
Description
Active Tags
The tags currently detected by any Receiver in the system. The system
removes a tag from this list if no Receiver has detected tag transmission for
more than 60 seconds.
Reference Tags
The reference tag(s), with the battery condition and operation status. The
reference tag status shows:
Down when a reference tag is not detected
Suspended when a reference is suspended from operation
Present when the battery level is in the recommended range
The reference tag battery level shows:
Low when the tag's battery is low and needs to be changed
Good when the tag’s battery is good