Operator`s manual

ZVac Models ZV110, ZV220, ZV440 Manual Zebra Skimmers Corp.
Page 6 888-249-4855 • www.ZebraSkimmers.com • Zebra Skimmers Corporation
Zebra Skimmers Corp. ZVac Models ZV110, ZV220, ZV440 Manual
888-249-4855 • www.ZebraSkimmers.com • Zebra Skimmers Corporation Page 7
3.1.2 Main Parts Key, ZV440 (Fig. 3.1.2)
1. Vacuum motor
2. Liquid ejector pump
3. Control Panel
4. Automatic level control
5. Safety lter
6. Swarf tank
7. Quick tting hose
8. Swarf tank cover
9. Fixed wheel
10. Liquid tank
11. Sight glass
12. Castors with brake
13. Liquid drain off gun tube
14. Cable connection
15. Fluid drain cock
16. Silencer
17. Gun connection
3.2 Description of Machine
The vacuum is ideal for extracting uids and small
quantities of swarf. Practical and functional, it is suit-
able for lathes, mills, and all machine tools where cool-
ants and swarf need to be separated.
3.3 Operating Principle
The machine simultaneously draws up swarf which
is separated and contained, and uid, which is drawn
into the main container.
When the liquid container is full, a level control
switches off the suction and then empties the liquid by
means of the pump.
The swarf is then removed by hand by means of the
swarf container.
3.5 Proper Use
The exhauster is designed to operate in shops where
metal swarf is removed from machining operations.
It can suck in and separate the metal portion of the
machining process (swarf) from the uid part ( cutting
uids), thus allowing both to be quickly recovered.
All other use is prohibited and will void the warranty.
3.6 Improper Uses
The following is a list of machine uses that should be
STRICTLY AVOIDED:
-Never operate in any environment where there is a
risk of explosion.
-Never open the container while machine is running.
-Never suck up lit cigarettes ends. This may cause l-
ter to catch re.
-Never use the vacuum on irregular ground or on
slopes exceeding 5%.
-Never open the door to the electric panel. This door
should only be opened by a qualied electrician once
the main power is cut by cord disconnection.
-It is forbidden to use the vacuum to suck petrols, sol-
vents, radioactive material, or other contaminants.
3.7 Residual Hazards
Danger of electrical shock:
The terminal strip that connects the main electricity to
the electrical panel remains powered by the main even
when the main switch has been turned to the zero “0
position.
3.4 Technical Data
ZV110 ZV220 ZV440
Voltage: 110v 240v 440v
Power phases: 1 1 3
Power in watts: 1460 1460 2550
Waterlift, max
(in.):
135 135 145
Airow, max
(cfm):
92 92 219
Liquid container: 55 55 55
Dimensions: 48x24x40 48x24x40 48x24x40
Weight (lbs.): 300 287 338
Insulation (class): B B F
Noise Level
(dBA):
70 70 73