Operator`s manual
ZVac Models ZV110, ZV220, ZV440 Manual Zebra Skimmers Corp.
Page 10 888-249-4855 • www.ZebraSkimmers.com • Zebra Skimmers Corporation
Zebra Skimmers Corp. ZVac Models ZV110, ZV220, ZV440 Manual
888-249-4855 • www.ZebraSkimmers.com • Zebra Skimmers Corporation Page 11
Figure 6.3.4
Figure 6.3.5
Checking Condition of Hoses (Fig. 6.3.4)
- Check tube “1” to make sure that it is in perfect
condition and correctly xed
- Also check condition of suction hose “3”, which is
highly exposed to wear and breakage due to its
suction function. Pull pipe “3” out by hand to re-
place
- Inspect for clogging in outlet “3” or “5”, scraping
any debris that may have accumulated
Checking/Replacing Power Cable (Fig. 6.3.5)
Only authorized electricians may perform this mainte-
nance
Model ZV110, ZV220
- Make sure that the power cable “1” is in good con-
dition. If not, replace as follows:
- Unscrew the three leads from terminals N, L,
ground
- Slacken cable clamp “2”, remove the cable “1” and
replace it with a new one possessing the identi-
cal characteristics (non-ame propagating NEO-
PRENE 3G 1,5 type)
Model ZV440
- Make sure that the power cable “1” is in good con-
dition. If not, replace as follows:
- Unscrew the three leads from terminals R, S, T,
ground
- Slacken cable clamp “2”, remove the cable “1” and
replace it with a new one possessing the identi-
cal characteristics (non-ame propagating NEO-
PRENE 4G 12,5 type)