Specifications
2SHUDWLRQ2YHUYLHZ 6HFWLRQ
$XWR&DOLEUDWLRQ
By default, this printer automatically sets the sensor levels and determines the length of
the label being used. To auto-calibrate:
1. Turn the printer On (O).
2. Load the media and close the printhead.
3. Press FEED. Two labels print, completing auto-calibration.
Auto-calibration works only when you are using non-continuous media (a gap or notch
separates each label).
Auto-calibration is performed when the printer is turned On (O) (if the printhead has been
opened) and whenever an error is cleared.
0DQXDO&DOLEUDWLRQ
Perform manual calibration whenever preprinted labels are being used or if the printer
does not auto-calibrate. To calibrate manually:
1. Turn the printer On (O).
2. Remove several labels from a section of the liner to thread the liner only through the
printer.
3. Press and hold FEED until the Error LED flashes once, then twice. Release FEED.
Refer to Table 2-1 for a complete listing of Feed Modes.
4. The printer sets the media sensor for the liner being used. After it makes this
adjustment, the roll automatically feeds until a label is positioned at the printhead.
5. Refer to Figure 2-19. A profile of the media sensor setting prints. Upon completion,
the printer saves the new settings in memory and the printer is ready for normal
operations.
1RWH7KHSULQWHUGRHVQRWDXWRFDOLEUDWHFRUUHFWO\ZKHQ\RXDUHXVLQJSUHSULQWHG
ODEHOV,IWKLVW\SHRIPHGLDLVEHLQJXVHGVHH0DQXDO&DOLEUDWLRQRQSDJH
1RWH5HIHUWR7DEOH 3HUIRUPLQJDPDQXDOFDOLEUDWLRQGLVDEOHVWKHDXWR
FDOLEUDWLRQIXQFWLRQ7RUHWXUQWRDXWRFDOLEUDWLRQHLWKHUGHIDXOWWKHSULQWHURUUHIHUWR
\RXUODEHOSUHSDUDWLRQVRIWZDUHXVHUVJXLGH
1RWH:KHQXVLQJEODFNPDUNRUZHEODEHOVVHWWKHDSSURSULDWHVRIWZDUHFRPPDQG
VHH\RXUODEHOSUHSDUDWLRQVRIWZDUHXVHUVJXLGHEHIRUHSHUIRUPLQJDPDQXDO
FDOLEUDWLRQ