User`s manual

Settings and Adjustments
Laminator Station Adjustments
980541-003 Rev. A P630i, P640i Card Printer User’s Manual 67
Length Adjust (mils) This is the length of the laminate “patch”. If the patch is too long,
decrease this number, and vice versa.
Horizontal Offset (mils) Adjusts laminate placement on the card.
Heater Temperature This is the set point - temperature desired - not the actual
temperature. For actuals, see Sensor Data, preceding page. NOTE: Temperatures are
monitored by thermocouples at the
core of the heated rollers. Surface temperatures may differ
significantly.
Line Voltage If Auto is selected, the printer guesses line voltage based on line frequency,
assuming that 110V will be @ 60Hz, and 230V @ 50Hz. If this isn’t the case in your locality,
the printer will guess wrong, and you should set the voltage manually.
Caution • Do not set the temperature ABOVE 180°C, or BELOW room temperature
Caution • Running the printer at 220V, 60Hz in Auto mode may cause premature failure of
the heaters. Running the printer at 110V, 50Hz in Auto mode may cause abnormally long heat-
up time and poor temperature control.