Specifications

5 - 18 MK3000 MicroKiosk for Windows CE 5.0 Product Reference Guide
Calibrating the Screen
Use the Calibration screen to align the touch screen:
1. Remove and restore power to the MK3000 to reboot.
Figure 5-18
Calibration Screen
2. Carefully press and briefly hold the stylus tip on the center of the Calibration screen target. Repeat the
procedure as the target moves and stops at different locations on the screen.
3. The Confirm Calibration screen displays. Tap the screen to accept the settings, or wait 30 seconds and the
MK3000 returns to the Calibration screen.
TCM Error Messages
TCM validates the cells in the partition table when you click the Execute button. Cells highlighted in red contain
an error. Partition loading is disabled until all errors are corrected.
NOTE To access the Calibration screen from the Windows CE Control Panel, tap Start > Settings > Control
Panel. Double-tap the Stylus icon, tap the Calibration tab, and tap the Recalibrate button. The
Calibration screen appears.
Table 5-3
TCM Error Messages
Error Description/Solution
Failed to build images: flash
file system DLL not loaded!
TCM could not load the DLL required to build images for the targeting flash
file system. Reinstall TCM or recover the DLL.
Failure finding directory xxx Building process failed because directory xxx was not found.
Failure creating volume Building process failed because a certain disk volume could not be created.
Failure adding system file to
image
Build process failed because TCM failed to add a certain system file to the
disk image.
INVALID PATH The path for the image file to build is not valid.
Nothing Selected To Build In the Config Build window, no item is selected to build.
Illegal ESS ID In the Build ESSID Partition window, no ESS ID was entered or the ESS ID