User`s manual

Interfaces
58
980548-001 Rev. A KDU Plus User’s Manual 6/12/06
AUX1 and AUX2 Serial Port Configuration
Interface signal meet standard RS-232 requirements.
The AUX1 and AUX2 port are active in Forms and Terminal modes.
PS/2 Style Port (6-Pin DIN) Configuration
This port supports PS/2 Set 2 Scan Codes.
PIN NAME DIRECTION
1 NOT USED NOT USED
2 NOT USED NOT USED
3 RXD FROM AUX DEVICE
4 NOT USED NOT USED
5 GND GND
6 DSR TO AUX DEVICE
7 NOT USED NOT USED
8 CTS TO AUX DEVICE
9 +5V +5V TO AUX DEVICE
Pin Connection
1Data
2 NOT USED
3GND
4 +5V INPUT
5CLK
6 NOT USED