User`s manual

57
Interfaces
6/12/06 KDU Plus User’s Manual 980548-001 Rev. A
COM/PRINTER Serial Port Configurations
The +5 volts from the printers (pins 1 and 9) provide power for the KDU Plus and any
additional input devices attached to the KDU Plus.
Maximum total current draw for printers with ZPL hardware architecture: 750mA
Maximum total current draw for printers with EPL hardware architecture: 250mA
The KDU Plus’s current without external input devices attached is: 50mA
Caution The KDU Plus’s input ports (AUX1, AUX2, and PS/2 style) are not fused.
Exceeding the total current draw available could damage the your input device, KDU Plus,
or printer.
PIN
KDU Plus is DCE
PRINTER is DTE (ZPL)
KDU is DTE
PRINTER is DCE (EPL)
NAME DIRECTION NAME DIRECTION
1 NOT USED NOT USED +5V +5V FROM PRINTER
2 TxD TO PRINTER RxD FROM PRINTER
3 RxD FROM PRINTER TxD TO PRINTER
4 DTR FROM PRINTER CTS TO PRINTER
5 GND GND GND GND
6 DSR TO PRINTER DTR FROM PRINTER
7 RTS FROM PRINTER NOT USED NOT USED
8 CTS TO PRINTER RTS FROM PRINTER
9 +5V +5V FROM PRINTER NOT USED NOT USED
45mA*
120mA*
25mA*
( 45mA + 120mA + 25mA )
+ 50mA < Max. Current
50mA
* - Not real values
Current Draw