Set Mode/Language (for Real Time Clock)
Description: The ^SL command is used to specify the Real Time Clock’s mode of
operation and language for printing information.
Format: ^SLa,b
Parameters:
a = mode
Accepted Values:
S = “Start Time” mode. This is the time that is read from the real
time clock when label formatting begins (when ^XA is
received). The first label will have the same time placed on it
as the last label.
T = “Time Now” mode. This is the time that is read from the real
time clock when the label to be printed is placed in queue to
be printed. Time now is similar to a serialized time or date
field.
Default Value: S
b = language
Accepted Values:
1 = English
2 = Spanish
3 = French
4 = German
5 = Italian
6 = Norwegian
7 = Portuguese
8 = Swedish
9 = Danish
10 = Spanish 2
11 = Dutch
12 = Finnish
Default Value: the language selected with ^KL or the front panel