^MP
Mode Protection
Description: The ^MP command is used to disable the various Mode functions on
the front panel. Once disabled, the settings for the particular mode function can no
longer be changed and the LED associated with the function will not light.
Since this command has only one parameter, each mode will have to be disabled
with an individual ^MP command.
Format: ^MPa
Parameters:
a = mode to protect
Accepted Values:
D = Disable Darkness Mode
P = Disable Position Mode
C = Disable Calibration Mode
E = Enable All Modes
S = Disable all Mode Saves. (Modes can be adjusted but values
will not be saved.)
W = Disable Pause Key
F = Disable Feed Key
X = Disable Cancel Key
M = Disable Menu Changes
Default Value: E
Example:
^XA^MPD^MPC^XZ
Comments: If the parameter is missing or invalid, the command will be ignored.
ZPL II Programming Guide Volume One: Command Reference for X.10