Media Darkness
Description: This ^MD command adjusts the darkness relative to the current
darkness setting. The minimum value is -30 and the maximum value is 30.
Format: ^MDa
Parameters:
a = media darkness level
Accepted Values: -30 to 30, depending on current value.
Initial Value at Power-up: 0
If no value is entered, this command is ignored.
Examples:
If the current value (value on configuration label) is 16, entering the command ^MD-9
would decrease the value to 7.
If the current value (value on configuration label) is 1, entering the command ^MD15
would increase the value to 16.
If the current value (value on configuration label) is 25, entering the command
^MD10 would only increase the value to 30 since that is the maximum value allowed.
Each ^MD command is treated separately in relation to the current value as printed
on the configuration label.
For example, this is what would happen if two ^MD commands were received.
Assume the current value is 15. An ^MD-6 command is received that changes
the current value to 9. Another command, ^MD2, is received. The current value
is changed 17. The two ^MD commands were treated individually with respect
to the current value of 15.
ZPL II Programming Guide Volume One: Command Reference for X.10