Specifications
ZPL Commands
^B4
26
45541L-004 Rev. A ZPL II Programming Guide 9/15/06
^B4
Code 49 Bar Code
Description The ^B4 command creates a multi-row, continuous, variable-length
symbology capable of encoding the full 128-character ASCII set. It is ideally suited for
applications requiring large amounts of data in a small space.
The code consists of two to eight rows. A row consists of a leading quiet zone, four symbol
characters encoding eight code characters, a stop pattern, and a trailing quiet zone. A separator
bar with a height of one module separates each row. Each symbol character encodes two
characters from a set of Code 49 characters.
•
^B4 has a fixed print ratio.
• Rows can be scanned in any order.
Format ^B4o,h,f,m
This table identifies the parameters for this format:
Important • For additional information about the Code 49 bar code is required, go to
www.aimglobal.org.
Parameters Details
o = orientation Accepted Values:
N = normal
R = rotated 90 degrees (clockwise)
I = inverted 180 degrees
B = read from bottom up, 270 degrees
Default Value: current
^FW value
h = height multiplier
of individual
rows
Accepted Values: 1 to height of label
Default Value: value set by
^BY
This number multiplied by the module equals the height of the
individual rows in dots. 1 is not a recommended value.