Specifications
ZPL Commands
^CI
112
45541L-004 Rev. A ZPL II Programming Guide 9/15/06
This table identifies the parameters for this format:
Parameters Details
a = desired character
set
Accepted values 0 - 12 are Zebra Code Page 850 with specific
character replacements. For details, see International Character
Sets on page 114 and/or Zebra Code Page 850 on page 342.
Accepted Values:
0 = Single Byte Encoding - U.S.A. 1 Character Set
1 = Single Byte Encoding - U.S.A. 2 Character Set
2 = Single Byte Encoding - U.K. Character Set
3 = Single Byte Encoding - Holland Character Set
4 = Single Byte Encoding - Denmark/Norway Character Set
5 = Single Byte Encoding - Sweden/Finland Character Set
6 = Single Byte Encoding - Germany Character Set
7 = Single Byte Encoding - France 1 Character Set
8 = Single Byte Encoding - France 2 Character Set
9 = Single Byte Encoding - Italy Character Set
10 = Single Byte Encoding - Spain Character Set
11 = Single Byte Encoding - Miscellaneous Character Set
12 = Single Byte Encoding - Japan (ASCII with Yen
symbol) Character Set
13 = Zebra Code Page 850 (see page 342)
14 = Double Byte Asian Encodings *
15 = Shift-JIS **
16 = EUC-JP and EUC-CN *
17 = Deprecated - UCS-2 Big Endian ****
18 to 23 = Reserved
24 = Single Byte Asian Encodings *
25 = Reserved
26 = Multibyte Asian Encodings with ASCII Transparency
* and ***
27 = Zebra Code Page 1252 (see page 344)
Initial Value at power-up:
0
s1
= source 1
(character output
image)
Accepted Values: decimals
0 to 255
d1
= destination 1
(character input)
Accepted Values: decimals
0 to 255
s2
= source 2
(character output
image)
Accepted Values: decimals 0 to 255