Specifications

101
ZPL Commands
^BX
9/15/06 ZPL II Programming Guide 45541L-004 Rev. A
Effects of ^BY on ^BX
w = module width (no effect)
r = ratio (no effect)
h = height of symbol
If the dimensions of individual symbol elements are not specified in the
^BD command,
the height of symbol value is divided by the required rows/columns, rounded, limited to a
minimum value of one, and used as the dimensions of individual symbol elements.
Field Data (^FD) for ^BX
Quality 000 to 140
•The \& and || can be used to insert carriage returns, line feeds, and the backslash, similar to
the PDF417. Other characters in the control character range can be inserted only by using
^FH. Field data is limited to 596 characters for quality 0 to 140. Excess field data causes
no symbol to print; if
^CV is active, INVALID-L prints. The field data must correspond to
a user-specified format ID or no symbol prints; if
^CV is active, INVALID-C prints.
The maximum field sizes for quality 0 to 140 symbols are shown in the table in the g
parameter.
Table 10 • Maximum Field Sizes
Example • This is an example of a Data Matrix bar code:
0
50
80
100
140
596
457
402
300
144
452
333
293
218
105
394
291
256
190
91
413
305
268
200
96
310
228
201
150
72
271
200
176
131
63
ECC
LEVEL
ID=1 ID=2 ID=3 ID=4 ID=5 ID=6
Maximum Field Sizes