Datasheet

Table Of Contents
Connections
Attaching Power
34
P1016701-001 Rev. B KR403 Hardware Integrator Guide 9/24/2010
Attaching Power
Caution • Never operate the printer and power supply in an area where they can get wet.
Serious personal injury could result!
The KR403 printer has unique power requirements to operate efficiently, safely and within
safety and compliance regulation guidelines. To achieve optimum performance, an
approved power supply should be used to operate the KR403 printer. Refer to "Printer
Power Supply – 808099-004" on page 76.
If a non-Zebra supplied power supply is used with the KR403, it must comply with the
following requirements.
Note • The printer does not have an integrated power switch.
Table 4-11 •
Power Supply Output Characteristics
Output Rating 24.0 Volts. 2.92 Amps and 2.5 Amps, +5° to +40° C
Voltage 24.0 Vdc +5/-2% Initial Tolerance, No Load)
Current 2.92A and 2.5AMaximum
Output Requirement When Printing (worst case conditions)
Max Output Power 24.0 Vdc x 2.92A = 70 Watts typical
Peak Power (90VA Cin, 47Hz) 243W
Output Regulation
Line Regulation ±0.5% over AC input operation range.
Ripple & Noise 240mVpp at lout = 2.92 Amps, Resistive Load
(4.7µF/50V ceramic Cap. On output, 20MHz BW)
Transient Load Response < 5mS Recovery, 40% to 80% Load Change
Overshoot, Power-Ip 10% Max at power-on or power-off
Holdup Time 20ms Minimum, Rated DC Load, 120VAC/60Hz
Over-Voltage Output Limited to +28V max.
Fuse Yes
Thermal Allowed, Not Required
Remark:
When short circuit protection or over-current protection is activated, the power supply will
shutdown automatically. Once the condition resulting in the failure is cleared, the power supply will
restart.
Automatic Recovery:
Over-voltage protection is activated, the power supply will shutdown. The power supply is fully
protected against short circuits and automatically recovers upon removal of the short without the
need for re-cycling the AC input voltage.