Installation guide

Installation Guide 7
1.5 Selecting a Site
Switch units can be mounted in a standard 19 inch equipment rack or on a flat surface. Be sure to follow the
guidelines listed below when choosing a site:
Locate the switch unit at the center of all devices you want to link and near a power outlet.
Maintain a temperature range within 0
° to 50° C / 32° to 122° F and humidity range within 10% to 90%
non-condensing.
Provide adequate space (approximately 2 inches) on all sides for proper air flow.
Confirm access for installing, cabling, and maintaining all devices.
Install the switch unit so that status LEDs are clearly visible.
Use only twisted-pair cables with RJ-45 connectors that conform to FCC standards.
Ensure that twisted-pair cables are always routed away from power lines, fluorescent lighting fixtures,
and other sources of electrical interference, such as radios and transmitters.
Ensure that the unit is connected to a separate grounded power outlet that provides 100 to 240VAC and
50 to 60Hz power levels.
Ensure that the unit is within 6.6 ft / 2m of each device that is powered from an independent circuit
breaker.
Use of a filter or circuit breaker is recommended.