4. Slide the transceiver into the slot until it clicks into place. If you do not immediately connect a cable to the
port, use a rubber protective cap to keep the transceiver optics clean.
3.4.2 Connecting Twisted-Pair Cables
The RJ-45 ports on the switch support automatic MDI/MDI-X pinout configuration, which enables you to use
standard straight-through twisted-pair cables to connect to any other network device (PCs, servers, switches,
routers, or hubs).
The connection requires an unshielded twisted-pair (UTP) or shielded twisted-pair (STP) cable with RJ-45
connectors at both ends.
To ensure proper operation when installing the switch into a network, make sure that the current cables are suitable
for 10BASE-T, 100BASE-TX, or 1000BASE-T operation. Check the following criteria against the current installation
of your network:
Cable type: UTP or STP cables with RJ-45 connectors; Category 5, 5e or better cable for 1000BASE-T
connections, Category 5 or better for 100BASE-TX connections, and Category 3 or better for 10BASE-T
connections.
Protection from radio frequency interference emissions
Electrical surge suppression
Separation of electrical wires (switch related or other) and electromagnetic fields from data based
network wiring
Safe connections with no damaged cables, connectors or shields
3.4.3 Cable Requirements
All Category 5 UTP cables that are used for 100BASE-TX connections should also work for 1000BASE-T, providing
that all four wire pairs are connected. However, it is recommended that for all critical connections, or any new cable
installations, Category 5e (enhanced Category 5) or Category 6 cable should be used. The Category 5e and Category
6 specifications include test parameters that are only recommendations for Category 5. Therefore, the first step in
NOTE To remove a transceiver, disconnect the network cable then pull the tab
to remove the transceiver from the slot.
Cable Type Maximum Cable Length Connector Type
100BASE-T
Category 5, 5e or 100-ohm UTP or STP
100 m (328 ft) RJ-45
100BASE-TX
Category 5 or better 100-ohm UTP or STP
100 m (328 ft) RJ-45
10BASE-T
Category 3 or better 100-ohm UTP
100 m (328 ft) RJ-45