EX-3524/EX-3548 Layer 2 Gigabit Ethernet PoE/PoE+ Switch INSTALLATION GUIDE
EX-3524/EX-3548 Layer 2 Gigabit Ethernet PoE/PoE+ Switch Zebra and the Zebra head graphic are registered trademarks of ZIH Corp. The Symbol logo is a registered trademark of Symbol Technologies, Inc., a Zebra Technologies company. © 2015 Symbol Technologies, Inc.
Installation Guide 1.0 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 1.1 Unpacking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 1.2 Document Conventions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 1.3 Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
EX-3524/EX-3548 Layer 2 Gigabit Ethernet PoE/PoE+ Switch 3.4 Port Connections. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 3.4.1 Installing SFP Transceivers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 3.4.2 Connecting Twisted-Pair Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 3.4.3 Cable Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 3.4.
Installation Guide 5 1 Introduction The EX-3524 and EX-3548 are Gigabit Ethernet Layer 2 switches with either 24 or 48 10/100/1000-BASE-T ports, and four Small Form Factor Pluggable (SFP) transceiver slots for fiber connectivity. The switches are built with leading-edge technology to deliver reliable high-performance connectivity for your data network. All of the 10/100/1000 Mbps ports on the switches support both the IEEE 802.3af and IEEE 802.3at-2009 PoE standards.
EX-3524/EX-3548 Layer 2 Gigabit Ethernet PoE/PoE+ Switch 1.3 Warnings • • • • • • • • • • • • • • • Read all installation instructions and site survey reports, and verify correct equipment installation before connecting the system to its power source. Remove jewelry and watches before installing this equipment. Verify any device connected to this unit is properly wired and grounded. Connect all power cords to a properly wired and grounded electrical circuit.
Installation Guide 7 1.5 Selecting a Site Switch units can be mounted in a standard 19 inch equipment rack or on a flat surface. Be sure to follow the guidelines listed below when choosing a site: • • • • • • • • • • Locate the switch unit at the center of all devices you want to link and near a power outlet. Maintain a temperature range within 0° to 50° C / 32° to 122° F and humidity range within 10% to 90% non-condensing. Provide adequate space (approximately 2 inches) on all sides for proper air flow.
2 EX-3524/EX-3548 Layer 2 Gigabit Ethernet PoE/PoE+ Switch Specifications 2.1 Physical Specifications Form factor 1U rack mount Dimensions (WxDxH) EX-3524: 44.0 x 28.0 x 4.4 cm (17.32 x 11.00 x 1.73 in) EX-3548: 44.0 x 40.9 x 4.4 cm (17.32 x 16.10 x 1.73 in) Weight EX-3524: 3.6 kg (7.83 lb) EX-3548: 6.6 Kg (14.55 lb) 2.
Installation Guide 9 2.4 Power Cord Specifications A power cord is not supplied with the EX-3524/EX3548 switch. Use only a correctly rated power cord certified (as appropriate) for the country of operation. 2.4.1 Power Protection • • • If possible, use a circuit dedicated to data processing equipment. Commercial electrical contractors are familiar with wiring for data processing equipment and can help with the load balancing of these circuits. Install surge protection.
EX-3524/EX-3548 Layer 2 Gigabit Ethernet PoE/PoE+ Switch 2.5.1 Port LEDs For information on port status LED indicators, see Port Status LEDs on page 13. 2.5.2 10/100/1000BASE-T RJ-45 Ports The switch contains 24 10/100/1000BASE-T RJ-45 ports that support 10/100/1000BASE-T copper links to other devices. For more information, see Connecting Twisted-Pair Cables on page 21. 2.5.
Installation Guide 11 2.5.8 Ground Point The switch should be connected to ground using this screw connection. For more information on how to connect ground to the switch, see Power and Grounding on page 18. 2.5.9 AC Power Socket The switch requires a 100-240 VAC, 50-60 Hz AC power source. For more information on the switch power input, how to connect it, and how to power-on the switch, see Power and Grounding on page 18.
EX-3524/EX-3548 Layer 2 Gigabit Ethernet PoE/PoE+ Switch 2.6 LED Codes 2.6.1 System Status LEDs The diagnostic and power LEDs located on the front panel are shown below and described in the following table: LED Condition Status DIAG Green Solid Amber Solid Blinking Amber Blinking Amber and Green System diagnostic test completed successfully System diagnostic test in progress or PoE button pressed System fault detected System booting up PWR Green Solid Off Internal power operating normally.
Installation Guide 13 2.6.2 Port Status LEDs The switch includes LEDs for each port to indicate link status and network activity. The port LEDs are shown below and described in the following table: LED Condition Status 1000BASET RJ-45 Ports (1 - 24 or 1 - 48) Link/Activity On/Blinking Amber On/Blinking Green Off Port has a valid 10/100 Mbps link. Blinking indicates traffic on the port. Port has a valid 1000 Mbps link. Blinking indicates traffic on the port. The link is down.
EX-3524/EX-3548 Layer 2 Gigabit Ethernet PoE/PoE+ Switch 3 Hardware Installation The switch is designed to be installed in either a standard 19-inch equipment rack or simply placed on a suitable desktop or shelf surface. If you will mount your switch in a rack then plan your rack installation and install the switch chassis in the rack. Be sure to take into account switch cooling requirements.
Installation Guide 2. Use the supplied rack mounting screws to secure the switch in the rack.
EX-3524/EX-3548 Layer 2 Gigabit Ethernet PoE/PoE+ Switch 3. Connect an external AC power source to the AC power socket. 4. Verify basic switch operation by observing the system LEDs. For normal operation, both the DIAG and PWR LEDs should be solid green.
Installation Guide 17 5. Install the SFP transceivers and connect the cables to the port interfaces. • For RJ-45 ports, use 100-ohm category 3 or better Ethernet cable for 10BASE-T connections, use 100-ohm category 5 or better Ethernet cable for 100BASE-TX and 1000BASE-T connections. • Install SFP transceivers and then connect fiber optic cabling to the transceiver ports. • Status LEDs should be clearly visible.
EX-3524/EX-3548 Layer 2 Gigabit Ethernet PoE/PoE+ Switch 3.2 Shelf or Desktop Installation The switch can be installed on any flat surface such as a desktop or shelf. To mount the switch on a flat surface: 1. Attach the four adhesive feet to the bottom of the switch. 2. Set the device on a flat surface near an AC power source, making sure there are at least two inches of space on all sides for proper airflow. 3. If installing multiple switches, attach four adhesive feet to each switch.
Installation Guide 19 The rear panel of the switch chassis includes a single hole grounding terminal. It must be connected to ground to ensure proper operation and to meet electromagnetic interference (EMI) and safety requirements. To ground the switch chassis: 1. Ensure the rack on which the switch is to be mounted is properly grounded and in compliance with ETSI ETS 300 253. 2. Ensure there is a good electrical connection to the grounding point on the rack (no paint or isolating surface treatment). 3.
EX-3524/EX-3548 Layer 2 Gigabit Ethernet PoE/PoE+ Switch 3.4 Port Connecctions 3.4.1 Installing SFP Transceivers The switch provides slots for optional (not provided) SFP transceivers. The supported transceiver types are listed below: • • • • • 1000BASE-SX 1000BASE-LX 1000BASE-LH 1000BASE-FX 1000BASE-T NOTE SPF transceivers are hot-swappable. The switch does not need to be powered off before installing or removing the transceiver. To install a SFP transceiver: 1.
Installation Guide 21 4. Slide the transceiver into the slot until it clicks into place. If you do not immediately connect a cable to the port, use a rubber protective cap to keep the transceiver optics clean. NOTE To remove a transceiver, disconnect the network cable then pull the tab to remove the transceiver from the slot. 3.4.
EX-3524/EX-3548 Layer 2 Gigabit Ethernet PoE/PoE+ Switch preparing existing Category 5 cabling for running 1000BASE-T is a simple test of the cable installation to be sure that it complies with the IEEE 802.3-2008 standards. 3.4.4 Power-over-Ethernet The switch supports both IEEE 802.3af and IEEE 802.3at-2009 PoE standards that enable DC power to be supplied from the switch’s RJ-45 copper ports to connected devices by utilizing certain pairs of the connecting Ethernet cable.
Installation Guide 23 3.4.5 Connecting to SFP Ports The switch provides four ports for SFP-compliant fiber-optic transceivers. All 1000BASE fiber optic ports operate at 1 Gbps full duplex. The 100BASE fiber optic ports operate at 100 Mbps full duplex. Fiber Bandwidth Cable Type 100BASE-SX 62.5/125 micron multimode Maximum Cable Length Connector Type 160 MHz.
EX-3524/EX-3548 Layer 2 Gigabit Ethernet PoE/PoE+ Switch 3. Connect one end of the cable to the SFP port on the switch and the other end to the SFP port on the other device. Since SFP connectors are keyed, the cable can be attached in only one orientation. 4. As a connection is made, check the Link LED on the switch to validate the connection is valid.
Installation Guide 4 25 Switch Management The RJ-45 Console port on the front panel of the switch is used to connect a console device to the switch for out-of-band console configuration. The console device can be a PC or workstation running a VT-100 terminal emulator, or a VT-100 terminal. A console cable is supplied with the switch for connecting to a PC’s RS-232 serial DB-9 DTE (COM) port.
EX-3524/EX-3548 Layer 2 Gigabit Ethernet PoE/PoE+ Switch 3. Configure the PC’s COM port required settings using VT-100 terminal emulator software (such as HyperTerminal) running on the management PC. The switch’s default console port settings are: • 115200 bps, 8 data bits, 1-stop bit and no parity 4.
Installation Guide 27 Press Button Duration Result Less than 3 seconds No change to settings From 3 seconds to less than 6 seconds Switch reboots using saved configuration file 6 seconds or greater Switch reboots using factory default settings
5 EX-3524/EX-3548 Layer 2 Gigabit Ethernet PoE/PoE+ Switch Regulatory Overview This guide applies to the following model numbers: EX-3524 and EX-3548. All Zebra devices are designed to be compliant with rules and regulations in locations they are sold and will be labeled as required. Local language translations are available at the following Website: www.zebra.com/support.
Installation Guide 29 Japan Voluntary Control Council for Interference (VCCI) Class A ITE Korea Warning Statement for Class A ITE Chinese Warning Statement for Class A ITE 5.5 PSE Alarm 5.6 Power Cord Safety Please read the following safety information carefully before installing the switch: Warning: Installation and removal of the unit must be carried out by qualified personnel only. The unit must be connected to an earthed (grounded) outlet to comply with international safety standards.
EX-3524/EX-3548 Layer 2 Gigabit Ethernet PoE/PoE+ Switch This unit operates under SELV (Safety Extra Low Voltage) conditions according to IEC 60950. The conditions are only maintained if the equipment to which it is connected also operates under SELV conditions. France and Peru only This unit cannot be powered from IT† supplies.
Installation Guide 31 La prise secteur doit se trouver à proximité de l’appareil et son accès doit être facile. Vous ne pouvez mettre l’appareil hors circuit qu’en débranchant son cordon électrique au niveau de cette prise. L’appareil fonctionne à une tension extrêmement basse de sécurité qui est conforme à la norme IEC 60950. Ces conditions ne sont maintenues que si l’équipement auquel il est raccordé fonctionne dans les mêmes conditions.
EX-3524/EX-3548 Layer 2 Gigabit Ethernet PoE/PoE+ Switch Die Netzsteckdose muß in der Nähe des Geräts und leicht zugänglich sein. Die Stromversorgung des Geräts kann nur durch Herausziehen des Gerätenetzkabels aus der Netzsteckdose unterbrochen werden. Cordon électrique - Il doit être agréé dans le pays d’utilisation Etats-Unis et Canada Le cordon doit avoir reçu l’homologation des UL et un certificat de la CSA. Les spécifications minimales pour un cable flexible sont AWG No. 18, ouAWG No.
Installation Guide 33 5.7 Waste Electrical and Electronic Equipment (WEEE) English: For EU Customers: All products at the end of their life must be returned to Zebra for recycling. For information on how to return product, please go to: www.zebra.com/weee. Français: Clients de l'Union Européenne: Tous les produits en fin de cycle de vie doivent être retournés à Zebra pour recyclage. Pour de plus amples informations sur le retour de produits, consultez: www.zebra.com/weee.
EX-3524/EX-3548 Layer 2 Gigabit Ethernet PoE/PoE+ Switch Malti: Għal klijenti fl-UE: il-prodotti kollha li jkunu waslu fl-aħħar tal-ħajja ta' l-użu tagħhom, iridu jiġu rritornati għand Zebra għar-riċiklaġġ. Għal aktar tagħrif dwar kif għandek tirritorna l-prodott, jekk jogħġbok żur: www.zebra.com/weee. Românesc: Pentru clienţii din UE: Toate produsele, la sfârşitul duratei lor de funcţionare, trebuie returnate la Zebra pentru reciclare. Pentru informaţii despre returnarea produsului, accesaţi: www.
Installation Guide 6 35 Support If you have a problem with your equipment, contact support for your region. Contact information is available at: www.zebra.com/support. When contacting support, please provide the following information: • Serial number of the unit • Model number or product name • Software type and version number Support responds to calls by e-mail, telephone, or fax within the time limits set forth in support agreements.
Zebra Technologies Corporation Lincolnshire, IL 60069 USA Zebra and the Zebra head graphic are registered trademarks of ZIH Corp. The Symbol logo is a registered trademark of Symbol Technologies, Inc., a Zebra Technologies company. © 2015 Symbol Technologies, Inc.