User's Manual

oB Command - Cancel Auto Bar Code Optimization
Description: This command allows the advanced program
-
mertodisablebarcode optimizationforrotated
(90° & 270°) bar codes.
Syntax: oB
Parameters: None
The oB command is a global printer com
-
mand.
It can not be issued inside of a form.
It must be issued prior to issuing a bar code
command (and printing).
To reapply bar code defaults, issue a o (small
letter“o”)command. SeepageC-63 forimpor-
tant details on the effects of using the o com-
mand.
Reset the printer with a ^@ command with
flash firmware printers or cycle printer power to
clearthe oB commandand return theprinter to
normal operation.
Zebra Technologies Corporation does not warrant,
support, or endorse the use of bar codes generated
bytheprinterafteraoBcommandhasbeenissued.
Zebra Technologies Corporation does not support
this feature other than withtheinformationsupplied
in this document.
3-64