User`s manual
R Command - Backup
escription Use this command to control the print position
-
ing. This command's positioning functions can:
•
Reposition the print position back towards the
Top of Form after printing a line (or lines).
•
Disable the reposition to Top of Form before
printing (R00).
•
Move the print position to the physical Top of
form. Issuing the Rnn (nn = 01 -25) com
-
mand in the first command line following a
form feed (FF), a print buffer command (p or
P), a reset condition (power-up, etc.) or as the
first command in a group of buffered com
-
mands will cause the printer to reposition to
the physical Top of Form.
Syntax
¬Rp
1
Parameters p
1
= Distance in millimeters to backup.
Range: 01 - 25 (1 = 1 millimeter)
00 = Disables automatic
backup to top of form.
❏ The printer will reset to the default position
for Top of Form after a print command (p or
P) has been sent to the printer.
❏
The default Top of Form position (or margin)
is approximately 1mm below the top edge of
the media (label).
❏
The R command cannot be used inside a
Buffered Label or to print a buffered label
(see the B, E, P, and p commands).
Example:
¬R05 :moves the first print line 5mm
:toward the top edge of the label
3-30