Specifications

Table Of Contents
Y Command - Serial Port Setup
Description Use this command to establish the serial port
communication parameters.
Syntax
Yp
1
,p
2
,p
3
,p
4
Parameters p
1
= Baud rate
p
1
Description
11 115,000 baud (115K)
57 57,600 baud (57K)
38 38,400 baud (38K)
19 19,200 baud
96 9,600 baud
48 4,800 baud
24 2,400 baud
12 1,200 baud
p
2
= Parity.
Values: O = Odd parity
E = Even parity
N = No parity.
p
3
= # Data bits.
Values: 7 = Seven data bits
8 = Eight data bits
p
4
= # Stop bits.
Values: 1 = One stop bit
2 = Two stop bits.
After receiving this command, the printer will
automatically reset enabling the new rate.
This command is not used for the TLP2044/46 print
-
ers. The serial port setup on these printers is per
-
formed by configuration switches on the rear of the
printer.
2-60
980009-001 Rev.F
COMMAND REFERENCE