C Command - Counter
Saving and
Protecting
Consecutive
Numbers in
Nonvolatile Memory
This feature is useful when the counter field rep
-
resents a serial number (or others types of num
-
bers) that should never be repeated. This
feature allows for automatic retrieval and incre
-
menting (or decrementing) of the previous
counter value used every time a form is re
-
trieved (and printed).
By placing one minus sign as the first character
of the prompt, the prompt will appear only once
after the form is retrieved, thereby protecting
the integrity of the data.
KDU Support: This table shows individual printer support for
internal
storage of counter data.
Model
Counter Data Storage Options
C---
2622, 2642 (2242), 3642 S S S
2122, 2142 S S S
2046 / 2044 S S S
2443 (Orion) Note 1 Note 1 N/A
2722 / 2742 Note 1 Note 1 N/A
2344 (Eclipse), 2746 Note 1 Note 1 N/A
2684 (Strata) Note 1 Note 1 N/A
P2242 / P2222 Note 1 Note 1 N/A
O = Option; S = Standard; N/A =Not Supported
Note 1 – Internally stored counter values are reset after cycling
printer power or sending a reset command or pressing the Cancel.
Flash Memory Printers - Storing counter values
(after power is cycled or a Reset) and the [--]
prompt option are only supported with KDUs built
after December 1999. These KDUs store the counter
data for later recall.
Single Digit
Summation with
Counters
Add or substract a single digit from the recalled
counter value in a form. If form recalled counter
C0 had a value of 3, then processing C0+1 or
C0-2 would yeild values of 4 and 1 respec
-
tively.