Specifications

Table Of Contents
p Command - Reset Top of Form Sensing
Description: This command allows the advanced program
-
mer to reset the default parameters for top of
form sensing. The command resets the tear,
peel, gap, black line, and cut positions that are
stored in the printer.
Syntax: pp
1
,p
2
,p
3
,p
4
,p
5
Parameters: p
1
= 0 (Default Value)
p
2
= 0 (Default Value)
p
3
= 0 (Default Value)
p
4
= 0 (Default Value)
p
5
= 0 (Default Value)
The p command is a global printer command.
It can not be issued inside of a form.
It must be issued prior to any other form con-
trol command.
Used for troubleshooting purposes only.
Issue all 5 command parameters (p
1-5
). Use
the default (0) parameter values only!
Example:
p0,0,0,0,0¿
Eltron does not support this feature other than the in
-
formation supplied in document. Do not use this
command to change printer control parameters.
Flash Programmed Printers - If this command
was used to correct printer operation, the printer
may need the printer’s firmware reloaded to help en
-
sure proper operation. The printer’s firmware may
be corrupted.
980009-001 Rev.F G-15
Appendix G - Advanced Programming