User`s manual

+OLP Command - Offset Overlaminate Patch
Description Specifies the relationship between card positions
and Ribbon Sync Markers used to place Lamination
Patches on cards.
Note that except for the first patch, the firmware can
use Ribbon Sync Marker sensing in concert with
Flag Sensor Increment sensing to determine Ribbon
Advance Step requirements for patch applications.
However, a Ribbon Initialization leaves the firm
-
ware without an associated history for Ribbon Step
requirements. Because of this, the firmware needs a
beginning step value for use only to position the rib
-
bon after an Initialization.
Note: This command only applies to P500
Laminator Stations and ribbons with Sync.
Markers.
Syntax
+OLPp1p2p3¿
Parameters p1 = Card Offset Count from Ribbon Sync. Marker sense to the
point p2 takes effect. Only used to synchronize lamina-
tion patches that follow Initializations
p2 = Offset between where patch applications start
p3 = Count where patch applications end
Default Settings
+OLP11014090¿
2-12 980081-001 Rev. F
P3xx M
P3xx C
P4xx
P500
P600
Max