User`s manual
2). A communication protocol serves to direct
commands through the common parallel interface
lines to either Module.
While not being designed around a master-slave
arrangement, Module 2 commands can neverthe
-
less be sent to Module 1. As with P500s, Module 2
commands sent to Module 1 require a #
1 preface.
Either module can have a Smart-Card Station
and/or a Magnetic Stripe Encoder, with an
associated command set. However, Eltron
recommends Module 1 as the best place to locate
these options. Also, the faster path for commands is
the direct route.
Max Secure Systems all have Extended Memory
and can include the following:
·
Print Station Module (Max3000 or Max3300)
·
Laminator and Die Cutter Module
·
Magnetic Encoder Module
None of the media used in the other printer models
is intended for use in this model. Instead, the follow-
ing are used:
Cards
The cards placed in the Input Hopper are
oversized White Chip Cards, either with or
without a Magnetic Stripe and with or with-
out a printable surface.
An additional card material is used. This clear
material feeds from a roll, and the printer has
a Shear that delivers card-sized sections to
the card path.
Max Secure Systems use 0.022-inch thick
White Cards for two-layer laminates and
0.015-inch thick White Cards for three-layer
laminates.
980081-001 Rev. F 1-5