&CDER Command (Continued)
p2 = Custom Data Select, as follows:
Value
Description - Raw Data Format
Read Forward - “Raw” Data
U
Track 1
U_
Track 1 read data with NULs in data string
V
Track 2
V_
Track 2 read data with NULs in data string
W
Track 3
W_
Track 3 read data with NULs in data string
Read Reverse - “Raw” Data
u
Track 1
u_
Track 1 read data with NULs in data string
v
Track 2
v_
Track 2 read data with NULs in data string
w
Track 3
w_
Track 3 read data with NULs in data string
p3 = Data Block Size Select in Bits
Where:
Acceptable values = 3, 4, 5, 6, and 7
The encoder cannot decode and convert “Raw”
data into ASCII data. The encoder only reports data
read after the process has completed.