User`s manual
&CDER Command - Read Custom Track Data
The card printer responds to commands (with data
or error codes) via the bi-directional serial interface
only. The card printer cannot respond to this com
-
mand, (other than flagging an error), through a par
-
allel interface. The card printer can operate with
both interfaces attached and communicating with
the printer.
Description Set the encoder to read a selected data format.
The &CDER command in conjunction with the
&CDEW command resets the encoder to the de
-
fault ISO track density and data format settings.
Note: To send this command directly to the
Max3000 Encoder, use an #21 Initiation in-
stead of just an Escape.
Syntax
&CDERp1
p2↵←ISO Data
&CDERp1
p2
p3↵←Raw Data
Parameters
p1 = Track Select: (values 1, 2, 3, or 0 (zero)).
Where:
0 resets ALL tracks to ISO default configuration parame-
ters.
p2 = Custom Data Select, as follows:
Value
Description - ISO Format Data
0
Resets ALL tracks to ISO default configuration
parameters.
Default Format Select
Q
ISO Track 1 Data Format to Track 1
R
ISO Track 2 Data Format to Track 2
S
ISO Track 3 Data Format to Track 3
Custom ISO Track Format Location
qX
Track 1 with ISO Track “X” Format
rX
Track 2 with ISO Track “X” Format
sX
Track 3 with ISO Track “X” Format
X = 1, 2, or 3 as the ISO default track format applied to the
selected track (e.g., Q=q1, R=r2, and S=s3.
2-70 980081-001 Rev. F
• P3xx M
•
•
•
•
•
P3xx C
P4xx
P500
P600
Max