User manual
7 - 4 DS4800 Series Corded Digital Imager Product Reference Guide
Parameters
This section describes the parameters controlling the IDC firmware and provides programming bar codes for
setting them.
To set parameters requiring a range of values, scan the parameter bar code followed by two, three, or four bar
codes from Appendix G, Numeric Bar Codes corresponding to the desired value. Scan two numeric bar codes
for parameters with a maximum value of less than 100, for example, IDC Minimum Text Length. IDC Delay
Time requires scanning three digits since the maximum value is 200. Leading zeros are required.
Alternatively, use the sample application to set parameters using the parameter name. The application
provides prompts and error checking to assist in setting the parameters correctly and easily. You must use an
application to set a parameter to a negative value, as the IDC X Coordinate can require.
Table 7-1
Intelligent Document Capture (IDC) Parameter Defaults
Parameter Parameter Name
Parameter
Number
Default
Page
Number
Intelligent Document Capture (IDC)
IDC Operating Mode
DocCap_MODE
594 Off
7-5
IDC Symbology
DocCap_SYMBOLOGY
655 001
7-6
IDC X Coordinate
DocCap_X
596 -151
7-7
IDC Y Coordinate
DocCap_Y
597 -050
7-7
IDC Width
DocCap_WIDTH
598 0300
7-8
IDC Height
DocCap_HEIGHT
599 0050
7-8
IDC Aspect
DocCap_ASPECT
595 000
7-9
IDC File Format Selector
DocCap_FMT
601 JPEG
7-9
IDC Bits Per Pixel
DocCap_BPP
602 8 BPP
7-10
IDC JPEG Quality
DocCap_JPEG_Qual
603 065
7-10
IDC Find Box Outline
Sig_FINDBOX
727 Disable
7-11
IDC Minimum Text Length
DocCap_MIN_TEXT
656 00
7-11
IDC Maximum Text Length
DocCap_MAX_TEXT
657 00
7-12
IDC Captured Image Brighten
Sig_BRIGHTEN
654 Enable
7-12
IDC Captured Image Sharpen
Sig_SHARPEN
658 Enable
7-13
IDC Border Type
DocCap_BORDER
829 None
7-14
IDC Delay Time
DocCap_DELAY
830 000
7-15
IDC Zoom Limit
Sig_MIN_PERCENT
651 000
7-15
IDC Maximum Rotation
Sig_MAX_ROT
652 00
7-16