User manual
7 - 16 DS4800 Series Corded Digital Imager Product Reference Guide
IDC Maximum Rotation
Parameter Name: Sig_MAX_ROT
Parameter # 652
Set the maximum rotation any edge of the form can have in relation to the decoder's horizontal or vertical axis
for it to be considered for capture. Set this to zero (the default) to disable all checking. This parameter only
applies in Anchored mode.
Scan the bar code below, followed by two bar codes from Appendix G, Numeric Bar Codes in the range of 00 to
45 decimal. The default is 00.
IDC Maximum Rotation