DS457 Fixed Mount Imager Quick Reference Guide
DS457 Fixed Mount Imager © 2011 Motorola Solutions, Inc. All rights reserved. Motorola reserves the right to make changes to any product to improve reliability, function, or design. Motorola does not assume any product liability arising out of, or in connection with, the application or use of any product, circuit, or application described herein.
Quick Reference Guide 3 Introduction The DS457 fixed mount imager is specifically designed for standalone applications, and OEM applications such as kiosks. The imager is extremely compact, provides easy and flexible integration of bar code imaging into a host device, and offers high-performance imaging on 1D and 2D bar codes. The DS457 is ideal for embedded medical diagnostic equipment and for conveyor lines in manufacturing environments.
DS457 Fixed Mount Imager Connecting the DS457 To connect the DS457 to a host: 1. Plug the 9-pin D-connector with the end marked SCANNER into the DS457. 2. If using an external switch and applicable host cable, plug the trigger cable into the female stereo connector on the flying lead of the 9pin D-connector. 3. Plug the host side connector into the appropriate port on the host. 4.
Quick Reference Guide 5 Capturing Data When scanning, the imager projects a red laser aiming pattern which allows positioning the bar code within its field of view. If necessary, the imager turns on its red LEDs to illuminate the target bar code. To scan a bar code, center the symbol in any orientation within the aiming pattern. Be sure the entire symbol is within the rectangular area formed by the cross pattern.
DS457 Fixed Mount Imager The imager can also read a bar code presented within the aiming pattern but not centered. The top examples in the following illustration show acceptable aiming options, while the bottom examples can not be decoded. 012345 012345 012345 012345 Upon successful decode, the DS457 beeps and its LED turns green.
Quick Reference Guide 7 Programming Bar Codes Following are some frequently used bar codes for programming the DS457. Set Defaults • Restore Defaults - Scan this bar code to reset all default parameters as follows. - If you previously set custom defaults by scanning Write to Custom Defaults in the Integration Guide, scan Restore Defaults to retrieve and restore the decoder’s custom default settings. - If you did not set custom defaults, scan Restore Defaults to restore the factory default values.
DS457 Fixed Mount Imager Host Types USB Device Type HID Keyboard Emulation (Default) Symbol Native API (SNAPI) with Imaging Interface Symbol Native API (SNAPI) without Imaging Interface
Quick Reference Guide USB Device Type (continued) CDC COM Port Emulation SSI over USB CDC 9
DS457 Fixed Mount Imager Serial Host Type SSI Host Standard RS-232 (Transmits Only ASCII Data)
Quick Reference Guide 11 Trigger Modes Presentation (default) When the DS457 detects an object in its field of view, it triggers and attempts to decode. The range of object detection does not vary under normal lighting conditions. This applies to decode mode only. In this mode the unit does not enter Low Power mode.
DS457 Fixed Mount Imager Host A host command issues the triggering signal. The DS457 interprets a trigger press as a level triggering option. Host Motion Enhancement for Presentation Mode Select Disable Motion Enhancement to revert to standard Presentation Mode behavior. Disable Motion Enhancement (Default) Select Enable Motion Enhancement to fine-tune engine and decoder behavior for bar codes moving quickly through the imager’s field of view.
Quick Reference Guide 13 Mobile Phone/Display Mode This mode improves bar code reading performance with target bar codes displayed on mobile phones and electronic displays.
DS457 Fixed Mount Imager Beeper and LED Indications The beeper and LED indicate imager status as follows: Indication Imager is on. Beeper N/A A bar code is successfully 1 beep decoded. LED Red Flash of green A programming parameter Fast warble Flash of was entered successfully. green Transmission error. Bar code data was not received by the host.
Quick Reference Guide 15 Troubleshooting Problem Possible Cause Possible Solutions No red LED or nothing happens during a capture attempt. No power to the imager. Check the system power. Confirm that the correct host interface cable is used. Imager cannot read the bar code. Interface/ Secure cable power cables connections. are loose. Connect power supply. Check for loose cable connections. Imager is not Program the imager to programmed read the type of bar code for that bar to be scanned.
DS457 Fixed Mount Imager Regulatory Information This device is approved under the Symbol Technologies, Inc. brand: Symbol Technologies, Inc., is a wholly owned subsidiary of Motorola Solutions, Inc. ("Motorola"). This guide applies to Model Number: DS457 All Motorola/Symbol devices are designed to be compliant with rules and regulations in locations they are sold and will be labeled as required. Local language translations are available at the following website: http://supportcentral.motorola.
Quick Reference Guide 17 • Keep objects that are used frequently within easy reach • Perform tasks at correct heights • Reduce or eliminate vibration • Reduce or eliminate direct pressure • Provide adjustable workstations • Provide adequate clearance • Provide a suitable working environment • Improve work procedures. Laser Devices COMPLIES WITH 21CFR1040.10 AND 1040.11 EXCEPT FOR DEVIATIONS PURSUANT TO LASER NOTICE NO. 50, DATED JUNE 24, 2007 AND IEC 60825-1 (Ed. 2.0), EN60825-1:2007.
DS457 Fixed Mount Imager LED Devices Complies with IEC/EN60825-1:2001 & IEC/EN62471:2006 For devices with Class 1M LED's the following label is used: Scanner Labeling LASER LIGHT - DO NOT STARE INTO BEAM. CLASS 2 LASER/1M LED PRODUCT LASERLICHT-NICHT IN DEN STRAHL BLICKEN. LASER/1M LED KLASSE 2. LUMIERE LASER-NE PAS REGARDER DANS LE FAISCEAU. APPAREIL A LASER/1M LED DE CLASSE 2. 630-680nm,1mw ▔ ܝ/('䕤ᇘ ࣓Ⳉ㾚ܝᴳ ㉏▔ ܝ0㉏/('ѻક Power Supply Use ONLY a LISTED Motorola, Type no. PWRS-14000 (5.
Quick Reference Guide 19 Radio Frequency Interference Requirements - FCC Note: This equipment has been tested and found to comply with the limits for a Class B digital device, FOR HOME OR OFFICE USE pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
DS457 Fixed Mount Imager Marking and European Economic Area (EEA) Statement of Compliance Motorola/Symbol hereby declares that this device is in compliance with all the applicable Directives, 2004/108/EC and 2006/95/EC. A Declaration of Conformity may be obtained from http://www.motorola.com/doc.
Quick Reference Guide 21 Waste Electrical and Electronic Equipment (WEEE) English: For EU Customers: All products at the end of their life must be returned to Motorola for recycling. For information on how to return product, please go to: http://www.motorola.com/recycling/weee. Български: За клиенти от ЕС: След края на полезния им живот всички продукти трябва да се връщат на Motorola за рециклиране. За информация относно връщането на продукти, моля отидете на адрес: http://www.motorola.com/recycling/weee.
DS457 Fixed Mount Imager Français : Clients de l'Union Européenne : Tous les produits en fin de cycle de vie doivent être retournés à Motorola pour recyclage. Pour de plus amples informations sur le retour de produits, consultez : http://www.motorola.com/recycling/weee. Italiano: per i clienti dell'UE: tutti i prodotti che sono giunti al termine del rispettivo ciclo di vita devono essere restituiti a Motorola al fine di consentirne il riciclaggio.
Quick Reference Guide 23 Românesc: Pentru clien ii din UE: Toate produsele, la sfâr itul duratei lor de func ionare, trebuie returnate la Motorola pentru reciclare. Pentru informa ii despre returnarea produsului, accesa i: http://www.motorola.com/recycling/weee. Slovenski: Za kupce v EU: vsi izdelki se morajo po poteku življenjske dobe vrniti podjetju Motorola za reciklažo. Za informacije o vraèilu izdelka obišèite: http://www.motorola.com/recycling/weee.
Service Information If you have a problem using the equipment, contact your facility’s Technical or Systems Support. If there is a problem with the equipment, they will contact Motorola Solutions Support at: http://supportcentral.motorola.com For the latest version of this guide go to: http://supportcentral.motorola.com Motorola Solutions, Inc. One Motorola Plaza Holtsville, New York 11742, USA 1-800-927-9626 http://www.motorolasolutions.