Instructions
Table Of Contents
- Warranty
- Revision History
- Table of Contents
- About This Guide
- Chapter 1 Getting Started
- Chapter 2 123Scan and Software Tools
- Chapter 3 Data Capture
- Chapter 4 Maintenance & Technical Specifications
- Chapter 5 Radio Communications
- Introduction
- Radio Communications Parameter Defaults
- Wireless Beeper Definitions
- Radio Communications Host Types
- Bluetooth Friendly Name
- Wi-Fi Friendly Mode
- Radio Output Power
- Bluetooth Radio State
- HID Host Parameters
- Reconnect Attempt Beep Feedback
- Out of Range Indicator
- Beep on Insertion
- Digital Scanner(s) To Cradle Support
- Batch Mode
- Persistent Batch Storage
- Page Button
- Page Options
- Bluetooth Classic Bluetooth and/or Low Energy (Cradle Parameter Only/ Cradle Host Only)
- Bluetooth Security
- Bluetooth Radio, Linking, and Batch Operation
- Chapter 6 User Preferences & Miscellaneous Options
- Introduction
- Scanning Sequence Examples
- Errors While Scanning
- User Preferences Parameter Defaults
- User Preferences
- Default Parameters
- Parameter Bar Code Scanning
- Beep After Good Decode
- Beep on
- Direct Decode Indicator
- Beeper Volume
- Beeper Tone
- Beeper Duration
- Suppress Power Up Beeps
- Decode Pager Motor
- Decode Pager Motor Duration
- Low Power Mode
- Timeout to Low Power Mode from Auto Aim
- DS3608-ER Power Mode
- Battery Preservation Mode
- Hand-held Trigger Mode
- Hands-free Mode
- Hand-held Decode Aiming Pattern
- Hands-free Decode Aiming Pattern
- Picklist Mode
- Outdoor Picklist Mode
- FIPS Mode
- Continuous Bar Code Read
- Unique Bar Code Reporting
- Decode Session Timeout
- Hands-free Decode Session Timeout
- Timeout Between Decodes, Same Symbol
- Timeout Between Decodes, Different Symbols
- Mobile Phone/Display Mode
- PDF Prioritization
- PDF Prioritization Timeout
- Presentation Mode Field of View
- Decoding Illumination
- Motion Tolerance (Hand-held Trigger Modes Only)
- Ranging Light Immunity
- Battery Threshold
- Add an Enter Key
- Transmit Code ID Character
- Prefix/Suffix Values
- Scan Data Transmission Format
- FN1 Substitution Values
- Transmit “No Read” Message
- Unsolicited Heartbeat Interval
- Product ID (PID) Type
- Product ID (PID) Value
- UID Parsing
- DPM Mode
- DPM Illumination Control
- DPM Rough Shiny Surface Decoding
- Ultra High Density DPM Decoding
- Chapter 7 Imaging Preferences
- Introduction
- Scanning Sequence Examples
- Errors While Scanning
- Imaging Preferences Parameter Defaults
- Imaging Preferences
- Operational Modes
- Image Capture Illumination
- Image Capture Autoexposure
- Fixed Exposure
- Gain/Exposure Priority for Snapshot Mode
- Snapshot Mode Timeout
- Snapshot Aiming Pattern
- Silence Operational Mode Changes
- Image Cropping
- Crop to Pixel Addresses
- Image Size (Number of Pixels)
- Image Brightness (Target White)
- JPEG Image Options
- JPEG Target File Size
- JPEG Quality and Size Value
- Image Enhancement
- Image File Format Selector
- Image Rotation
- Bits Per Pixel
- Signature Capture
- Signature Capture File Format Selector
- Signature Capture Bits Per Pixel
- Signature Capture Width
- Signature Capture Height
- Signature Capture JPEG Quality
- Video View Finder
- Video View Finder Image Size
- Chapter 8 USB Interface
- Introduction
- Connecting a USB Interface
- USB Parameter Defaults
- USB Host Parameter
- USB Device Type
- Symbol Native API (SNAPI) Status Handshaking
- USB Keystroke Delay
- USB CAPS Lock Override
- USB Ignore Unknown Characters
- USB Convert Unknown to Code 39
- Emulate Keypad
- Emulate Keypad with Leading Zero
- Quick Keypad Emulation
- USB Keyboard FN 1 Substitution
- Function Key Mapping
- Simulated Caps Lock
- Convert Case
- USB Static CDC
- Optional USB Parameters
- ASCII Character Set for USB
- Chapter 9 SSI Interface
- Chapter 10 RS-232 Interface
- Chapter 11 IBM Interface
- Chapter 12 Keyboard Wedge Interface
- Chapter 13 Symbologies
- Introduction
- Scanning Sequence Examples
- Errors While Scanning
- Symbology Parameter Defaults
- Enable/Disable All Code Types
- UPC/EAN
- Enable/Disable UPC-A
- Enable/Disable UPC-E
- Enable/Disable UPC-E1
- Enable/Disable EAN-8/JAN-8
- Enable/Disable EAN-13/JAN-13
- Enable/Disable Bookland EAN
- Decode UPC/EAN/JAN Supplementals
- User-Programmable Supplementals
- UPC/EAN/JAN Supplemental Redundancy
- UPC/EAN/JAN Supplemental AIM ID Format
- UPC Reduced Quiet Zone
- Transmit UPC-A Check Digit
- Transmit UPC-E Check Digit
- Transmit UPC-E1 Check Digit
- UPC-A Preamble
- UPC-E Preamble
- UPC-E1 Preamble
- Convert UPC-E to UPC-A
- Convert UPC-E1 to UPC-A
- EAN-8/JAN-8 Extend
- Bookland ISBN Format
- UCC Coupon Extended Code
- Coupon Report
- ISSN EAN
- Code 128
- Code 39
- Code 93
- Code 11
- Interleaved 2 of 5 (ITF)
- Discrete 2 of 5 (DTF)
- Codabar (NW - 7)
- MSI
- Chinese 2 of 5
- Matrix 2 of 5
- Korean 3 of 5
- Inverse 1D
- GS1 DataBar
- Composite
- 2D Symbologies
- Postal Codes
- Symbology-Specific Security Levels
- Report Version
- Macro PDF Features
- Chapter 14 Intelligent Document Capture
- Introduction
- The IDC Process
- PC Application and Programming Support
- Parameters
- IDC Operating Mode
- IDC Symbology
- IDC X Coordinate
- IDC Y Coordinate
- IDC Width
- IDC Height
- IDC Aspect
- IDC File Format Selector
- IDC Bits Per Pixel
- IDC JPEG Quality
- IDC Find Box Outline
- IDC Minimum Text Length
- IDC Maximum Text Length
- IDC Captured Image Brighten
- IDC Captured Image Sharpen
- IDC Border Type
- IDC Delay Time
- IDC Zoom Limit
- IDC Maximum Rotation
- Quick Start
- Chapter 15 Digimarc Barcode
- Chapter 16 Data Formatting: ADF, MDF, Preferred Symbol
- Chapter 17 OCR Programming
- Introduction
- OCR Programming Parameters
- Enable/Disable OCR-A
- OCR-A Variant
- Enable/Disable OCR-B
- OCR-B Variant
- Enable/Disable MICR E13B
- Enable/Disable US Currency Serial Number
- OCR Orientation
- OCR Lines
- OCR Minimum Characters
- OCR Maximum Characters
- OCR Subset
- OCR Quiet Zone
- OCR Template
- OCR Check Digit Modulus
- OCR Check Digit Multiplier
- OCR Check Digit Validation
- Inverse OCR
- OCR Redundancy
- Appendix A Standard Default Parameters
- Appendix B Country Codes
- Appendix C Country Code Pages
- Appendix D CJK Decode Control
- Appendix E Programming Reference
- Appendix F Sample Bar Codes
- Appendix G Alphanumeric Bar Codes
- Appendix H Numeric Bar Codes
- Appendix I ASCII Character Sets
- Appendix J Communication Protocol Functionality
- Appendix K Signature Capture Code
- Appendix L Non-Parameter Attributes
- Index
4 - 4 DS36X8 Digital Scanner Product Reference Guide
Digital scanner decodes
barcode, but does not
transmit the data to the
host.
Digital scanner is not programmed
for the correct host type.
Scan the appropriate host type
programming barcode. See the chapter
corresponding to the host type.
Interface cable is loose. Re-connect the cable.
Cradle is not programmed for the
correct host type.
Check digital scanner host parameters or
edit options.
Digital scanner is not paired to host
connected interface.
Pair digital scanner to the cradle by
scanning the
PAIR
barcode on the cradle.
Cradle has lost connection to the
host.
In this exact order: disconnect power
supply; disconnect host cable; wait three
seconds; reconnect host cable; reconnect
power supply; reestablish pairing.
If the digital scanner emits 4 long
low beeps, a transmission error
occurred.
This occurs if a unit is not properly
configured or connected to the
wrong host type.
Set the scanner's communication
parameters to match the host's setting.
If the digital scanner emits 5 low
beeps, a conversion or format error
occurred.
Configure the digital scanner's conversion
parameters properly.
If the digital scanner emits
low/high/low beeps, it detected an
invalid ADF rule.
Program the correct ADF rules. Refer to
the Advanced Data Formatting
Programmer Guide.
Host displays scanned data
incorrectly.
Digital scanner is not programmed
to work with the host.
Scan the appropriate host type
programming barcode.
For RS-232, set the digital scanner's
communication parameters to match the
host's settings.
For a Keyboard Wedge configuration,
program the system for the correct
keyboard type, and turn off the CAPS
LOCK key.
Program the proper editing options (e.g.,
UPC-E to UPC-A Conversion).
Digital scanner emits short
low/short medium/short high
beep sequence (power-up
beep sequence) more than
once.
The USB bus may put the digital
scanner in a state where power to
the scanner is cycled on and off
more than once.
Normal during host reset.
Table 4-1 Troubleshooting (Continued)
Problem Possible Causes Possible Solutions