Instructions

Table Of Contents
14 - 18 DS36X8 Digital Scanner Product Reference Guide
IDC Delay Time
Parameter Name: DocCap_DELAY
Parameter # 830 (SSI # F2h 3Eh)
Set the delay for capturing a document after a trigger pull. Decoding a barcode aborts this delay. This parameter
only applies in Free-Form mode.
Scan the barcode below, followed by three barcodes from Appendix H, Numeric Bar Codes in the range of 000 to
200 decimal in units of 10 msec. The default is 000.
IDC Zoom Limit
Parameter Name: Sig_MIN_PERCENT
Parameter # 651 (SSI # F1h 8Bh)
Set the minimal "zoom" percentage value of a form for it to be considered for capture. This controls the quality of
the captured form. The IDC firmware rejects capturing a form unless the width is at least the IDC Zoom Limit
percentage of the IDC Width parameter. For example, if you set this parameter to 100 and IDC Width to 150, the
form must be at least 300 pixels wide before it is captured (each unit module is scaled to two pixels).
Set this to zero (the default) to disable all checking. This parameter only applies in Anchored mode.
Scan the barcode below, followed by three barcodes from Appendix H, Numeric Bar Codes in the range of 000 to
100 percent. The default is 000.
NOTE IDC pertains to the DS36X8-HP configuration only.
IDC Delay Time
NOTE IDC pertains to the DS36X8-HP configuration only.
IDC Zoom Limit